MD380 User Manual Desc
ription of Function Codes
- 171 -
This parameter is used to determine the corresponding setting when the analog input
voltage is less than the minimum value. The unit's digit, ten's digit and hundred's digit of this
parameter respectively correspond to the setting for AI2, AI2 and AI3.
If the value of a certain digit is 0, when analog input voltage is less than the minimum input,
the corresponding setting of the minimum input (F4-14, F4-19, F4-24) is used.
If the value of a certain digit is 1, when analog input voltage is less than the minimum input,
the corresponding value of this analog input is 0.0%.
F
unction Code
Parameter Name
Setting Range
Default
F
4-35
DI1 delay time
0.0–3600.0s
0.0s
F
4-36
DI2 delay time
0.0–3600.0s
0.0s
F
4-37
DI3 delay time
0.0–3600.0s
0.0s
These parameters are used to set the delay time of the AC drive when the status of DI
terminals changes.
Currently, only DI1, DI2 and DI3 support the delay time function.
F
unction Code
Parameter Name
Setting Range
Default
F
4-38
DI valid mode
selection 1
Unit's digit (DI1 valid mode)
00000
0: High level valid
1: Low level valid
Ten's digit (DI2 valid mode)
0, 1 (same as DI1)
Hundred's digit (DI3 valid mode)
0, 1 (same as DI1)
Thousand's digit (DI4 valid mode)
0, 1 (same as DI1)
Ten thousand's digit (DI5 valid mode)
0, 1 (same as DI1)
F
4-39
DI valid mode
selection 2
Unit's digit (DI6 valid mode)
00000
0, 1 (same as DI1)
Ten's digit (DI7 valid mode)
0, 1 (same as DI1)
Hundred's digit (DI8 state)
0, 1 (same as DI1)
Thousand's digit (DI9 valid mode)
0, 1 (same as DI1)
Ten thousand's digit (DI10 valid
mode)
0, 1 (same as DI1)
Содержание HD380-5T0.7GB
Страница 1: ...High Performance AC Drive MD380...
Страница 9: ......
Страница 10: ...1 Safety Information and Precautions...
Страница 17: ...Safety Information and Precautions MD380 User Manual 16...
Страница 18: ...2 Product Information...
Страница 29: ...Product Information MD380 User Manual 28...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 46: ...4 Operation Display and Application Examples...
Страница 79: ...Operation Display and Application Examples MD380 User Manual 78...
Страница 80: ...5 Function Code Table...
Страница 136: ...6 Description of Function Codes...
Страница 248: ...7 EMC...
Страница 260: ...8 Selection and Dimensions...
Страница 285: ...Selection and Dimensions MD380 User Manual 284...
Страница 286: ...9 Maintenance and Troubleshooting...
Страница 298: ...MD380 Series High Performance AC Drive...