AAY2000IKI06
25
Installation manual
Ingeteam Power Technology, S.A.
5.3.2. Order in which the equipment connections should be made
Ensure that the connection polarity is correct in all cases
The basic equipment connections should be made in the following order:
1.
Connection of the analog inputs (optional).
2.
Communication line.
3.
Connection of the DC OUTPUT to the Ingecon
®
µWind DC quick connectors.
4.
Connection of the braking resistors.
5.
Connection with the wind turbine.
6.
Connection of the auxiliary power supply.
The following sections describe how these connections should be made.
5.3.3. System diagram
The system diagram corresponds to the configurations found in the majority of installations.
The regulations applicable to each installation and to each country in which the equipment is to be located, should
always be complied with.
Wiring diagram for the Ingecon
®
µWind TL equipment with a connection to the Ingecon
®
μWind Interface (IWI)
For Ingecon
®
µWind 2.5 TL, 3 TL, 3.3 TL, 3.68 TL, 4.6 TL, 5 TL and 6TL Interfaces with a connection to the
Ingecon
®
μWind Interface.
wind turbine
thermal magnetic
breaker
electricity company panel
kWh meter
grid
μ
Wind
IWI
Wiring diagram for the Ingecon
®
µWind TL equipment with a transformer and connection to the Ingecon
®
μWind Interface (IWI)
For Ingecon
®
µWind 2.5, 3.3 and 5 Interfaces with a connection to the Ingecon
®
μWind Interface.
wind turbine
thermal magnetic
breaker
transformer
electricity company panel
kWh meter
grid
μ
Wind
IWI
5.3.4. Communication
The communication system between the Ingecon
®
μWind Interface and the Ingecon
®
µWind allows both items of
equipment to operate together, in addition to the remote control and system monitoring tasks.
The process for the correct connection of the communication system is as follows: