AAY2000IKI06
10
Installation manual
Ingeteam Power Technology, S.A.
1.2.1. Functional diagram of the equipment
resistors*
Ingecon
®
μWind Interface
communications
interlock
contactors
rectifier
controller
analog inputs
* resistors are not included with the equipment.
1.2.2. Options
For special applications, the Ingecon
®
μWind Interface features two digital opto-isolated inputs for voltages of 0 ~
24V. In addition to two potential free contacts that can be used as digital communication outputs or as a system to
activate the auxiliary braking systems or Pitch control system.
Optionally, it can access the Ingecon
®
Manager software to monitor system configuration, variables, and remote
control.
1.3. Compliance with standards and regulations
The Ingecon
®
μWind Interface models can be fitted with kits to adapt them to the standards and regulations in all
European countries and also those in force in other continents.
1.3.1. CE Marking
The CE marking is essential for marketing any product in the European Union, without prejudice to all applicable
standards and regulations. The Ingecon
®
μWind Interface models bear the CE Marking through compliance with the
following directives:
•
Low Voltage Directive
2006/95/EC
•
Electromagnetic Compatibility Directive
2004/108/EC
Low Voltage Directive
The Ingecon
®
μWind Interface models are sufficiently compliant with this directive by compliance with the applicable
parts of harmonised standard
EN 50178 Electronic for use in power installations
.
Electromagnetic Compatibility Directive
The Ingecon
®
μWind Interface models are sufficiently compliant with this directive by compliance with the applicable
parts of the following harmonised standards:
•
EN 61000-6-2 Electromagnetic Compatibility. Part 6-2: Generic Standards - Immunity for Industrial
Environments.
Содержание Ingecon mWind Interface
Страница 1: ...Ingecon Wind Interface Installation manual...
Страница 34: ...Notes...