Chapter 2 - Commissioning
17
XtrapulsCD1-pm - User manual
11 - MOTOR PHASING AT POWER ON
In the Incremental encoder configuration without HES, the motor Phasing procedure is executed according to the
following diagram at each amplifier power up (standalone mode) :
In the Profibus mode, the phasing procedure must be started by the master controller (PNU 896). In the Software
control mode via the serial link, the phasing procedure must be started by the Motor phasing command in the
VDSetup
window.
Remark: In the Incremental encoder configuration without HES, the motor
Phasing
procedure must be carried out
again after a
Feedback
fault release or a
Counting
fault release. The motor
Phasing
procedure must also be
carried out again after the modification of the motor or the encoder parameter value.
- The analog output on the X2 connector can be configured in the
Setup
menu of the
VISUAL DRIVE SETUP
software in order to get the
Phasing OK
output signal (output voltage from 0 V to 10 V when the motor phasing is
OK) .
- In the Profibus mode, the
Phasing OK
can be checked by the master controller (PNU 897).
- In the Software control mode via the serial link, the state of the
Phasing OK
output is displayed in the main
VDSetup
window.
12 - INCREMENTAL ENCODER OUTPUTS
The incremental encoder outputs are two pulse channels A and B in quadrature and one Z marker pulse per
revolution.
AOK
Power On
ENABLE
PHASING OK
Start up
Power on
Phasing
Ready for running
Start phasing
End start up
End phasing
In the case of an axis with unbalanced load (constant torque due to the gravity effect on a
vertical axis), the motor phasing procedure is not valid. The motor must be equipped with an
incremental e HES or an absolute Sin/Cos encoder.
!