Chapter 2 - Commissioning
10
XtrapulsCD1-pm - User manual
2
– INSTALLATION OF THE PC SOFTWARE
The
Visual Drive Setup
software is PC compliant under Windows
® 1
and allows an easy parameterization of the
XtrapulsCD1-pm
amplifiers.
Please see our website
www.infranor.com
for downloading the "Visual Drive Setup" software.
3 - CHECKING THE POSITIONER HARDWARE CONFIGURATION
The standard amplifier configuration is adjusted to MAVILOR motors (resolver sensor with transformation ratio =
0.5). For the adjustment to other motor types, please see "
XtrapulsCD1
-pm - Installation Guide
".
4 - SELECTION OF THE OPERATION MODE
A DIP micro-switch, accessible by the operator, allows the selection of the various operation modes.
7 6 5 4 3 2 1
(Switch 7 = MSB
Switch 1 = LSB)
Operation mode
Note
X0000000 (00)
Profibus software addressing
This mode is compliant with the CD1-p drive
Drive address is stored into the EEPROM
X0000001 (01) to X1111101 (7D)
Profibus hardware addressing
Profibus mode with hardware addressing via
"DIP" switch
X1111111(7F)
Stand-alone Mode without VT100
Drive used in Positioner mode via inputs
START, STOP, IN1 to IN6
X1111110(7E)
Stand-alone Mode with VT100
Drive used in Positioner mode via inputs
START, STOP, IN1 to IN6
Possible use of a VT100 terminal
X: Cursor unused.
Remark: The positioner automatic procedure for the commissioning phase (autophasing, autotuning, cogging
torque acquisition ...) cannot be started in the stand-alone operation mode .
5 - COMMISSIONING
Please see manual "
XtrapulsCD1-pm - Installation Guide
" before switching on the amplifier for the first time.
For switching on the amplifier, please proceed as follows:
•
Switch on the +24V auxiliary supply:
The red front panel LED "
ERROR
" must be unlit and the red front panel LED "
AP
" must be lit ("Undervolt." error
displayed).
The AOK relay contact (pins 1 and 2 of X4) is closed. It is then possible to control the power ON relay.
•
Switch on the power supply:
The red front panel LED "
AP
" must be unlit : the amplifier is ready for enabling.
1
Windows
®
is a registered trade mark of MICROSOFT
®
CORPORATION
CAUTION !
The 24 V auxiliary supply must
always
be switched on
before
the power supply.
It is mandatory to wait for at least 30 seconds between switching off and on again the amplifier.