Appendix
51
XtrapulsCD1-pm - User manual
Inputs/Outputs status
Instruction
IO
Parameters
None
Conditions
Read only
Notes
This instruction reads the logic inputs and outputs status
bit
meaning
0
START
1
STOP
8
SEQ
9
POS
10
SPEED
16
IN1
17
IN2
18
IN3
19
IN4
20
IN5
21
IN6
22
IN7
23
IN8
24
OUT1
25
OUT2
26
OUT3
27
OUT4
28
OUT5
29
OUT6
30
OUT7
31
OUT8
- Bit SEQ indicates that the positioner is running a sequence.
- A sequence can be executed when bit STOP is not activated (equal to 0), and also if the
security of the first sequence (HOME) is disabled.
Absolute move
Instruction
MP
Parameters
absolute position
Conditions
"Enable" and "Run" signals are activated.
Note
Unit
See "
modify position of a sequence".
Speed (absolute move)
Instruction
DS
Defines the speed for an absolute movement (MP).
Parameters
Speed
Conditions
Note
This parameter is saved in the positioner memory. When the maximum speed parameter value
is changed, this parameter value is scaled accordingly.
Unit
rpm
Acceleration (absolute move)
Instruction
DA
defines the acceleration for an absolute movement (MP).
Parameters
acceleration time
Conditions
Note
The parameters
acceleration time
and
deceleration time
define the time with regard to the
maximum speed parameter value. When the motion speed is lower than the maximum speed,
the trajectory acceleration and deceleration times are proportionally reduced.
This parameter is saved in the positioner memory.
Unit
Millisecond