For checking the limit switches:
-
move the motor in one direction in speed mode,
-
activate the limit switch which is located in the motion direction (artificially, if necessary),
-
check that the motor is stopping,
-
if the motor does not stop, the limit switches are reversed wired.
Check also in the opposite direction.
Notes
-
The motor is stopped with maximum deceleration by a limit switch.
-
Reminder: The limit switches are wired as "normally closed".
3 - BRAKE CONTROL
•
The XtrapulsCD1-pm positioner is equipped with a brake control (made by transistor).
•
The brake control is activated (relay open) or disabled (relay closed) according to the positioner status
(disabled or enabled) as shown below.
4 - PROFIBUS ADDRESS
4.1 - PROFIBUS SOFTWARE ADDRESSING
This operation mode is selected with all the DIP micro-switches on position OFF.
Each positioner of the network is identified by one single address (1 to 125). The positioner is delivered with the
default software address 126,
which is not an operational address
. This address must be modified before
putting the bus into operation.
The XtrapulsCD1-pm software address can be modified:
- by the serial RS-232 link (PC parameterization software). The new address must be saved in the EEPROM
and the positioner must be switched on again in order to get the new address operational;
- or by a Profibus class 2 master device
.
The address modification is only possible when the bus is not
running. In this case, the address will be automatically saved in the positioner EEPROM and will be
operational at the bus starting.
The identity number of the XtrapulsCD1-pm positioners under Profibus is 0x00C7.
4.2 - PROFIBUS HARDWARE ADDRESSING
In this operation mode, the XtrapulsCD1-pm address (1 to 125) is selected by means of the DIP micro-switches 1
to 7. DIP micro-switch 1 is the LSB and DIP micro-switch 7 is the MSB.
The selected hardware address is operational at the XtrapulsCD1-pm amplifier power on, regardless of the
software address saved in the EEPROM.
The XtrapulsCD1-pm address can be modified by a Profibus class 2 master device
.
The address modification is
only possible when the bus is not running. In this case, the address will be automatically saved in the positioner
EEPROM. However, at the next XtrapulsCD1-pm power on, the selected hardware address is still operational.
The identity number of the XtrapulsCD1-pm positioners under Profibus is 0x00C7.
Motor enabled
Brake OFF delay
Brake ON delay
Enable
command
Brake control
output