Appendix
50
XtrapulsCD1-pm - User manual
Modify acceleration of a sequence
Instruction
YA
Parameters
1st parameter: sequence number.
2nd parameter: acceleration time.
If there is no 2nd parameter, the amplifier will return the actual acceleration time of the
sequence (1st parameter).
Conditions
This instruction can be sent only if no sequence is executed.
The sequence must exist.
Unit
Millisecond
Range
16 ms - 16000 ms
Note
The parameters
acceleration time
and
deceleration time
define the time with regard to the
maximum speed parameter value. When the motion speed is lower than the maximum speed,
the trajectory acceleration and deceleration times are proportionally reduced.
Remark
The parameter modification takes effect immediately, but the parameter value is modified in the
drive RAM memory only. A WR80 command must be executed if the modification must be
saved into the drive EEPROM.
Modify deceleration of a sequence
Instruction
YD
Parameters
1st parameter: sequence number.
2nd parameter: deceleration time.
If there is no 2nd parameter, the amplifier will return the actual deceleration time of the
sequence (1st parameter).
Conditions
This instruction can be sent only if no sequence is executed.
The sequence must exist.
Unit
Millisecond
Range
16 ms - 16000 ms
Note
The parameters
acceleration time
and
deceleration time
define the time with regard to the
maximum speed parameter value. When the motion speed is lower than the maximum speed,
the trajectory acceleration and deceleration times are proportionally reduced.
Remark
The parameter modification takes effect immediately, but the parameter value is modified in the
drive RAM memory only. A WR80 command must be executed if the modification must be
saved into the drive EEPROM.
Sequences saving into the drive
Instruction
WR
Parameters
0x80.
Conditions
Amplifier disabled.
Note
The full sequences writing into the EEPROM takes many seconds. Wait for the drive reply
before writing other parameters. If the saving operation is aborted, the drive will indicate an
EEPROM fault at its next 24 V powering.
Execution of a sequence
Instruction
GO
Parameters
1st parameter : sequence number.
Conditions
This instruction can be sent only if no sequence is executed.
"Enable" signal is activated.
"Stop" inputs are not activated.
The sequence must exist.
Note
This instruction executes a sequence (with parameter as sequence number) regardless of the
logic inputs status.
Position feedback
Instruction
PF
Parameters
none
Conditions
Read only
Note
This instruction reads the motor position.
Unit
See "
modify position of a sequence".