![Infranor XtrapulsCD1-pm Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/infranor/xtrapulscd1-pm/xtrapulscd1-pm_user-manual_2058369011.webp)
Chapter 2 - Commissioning
11
XtrapulsCD1-pm - User manual
6 - STARTING THE "VDSETUP" SOFTWARE
•
Connect the serial link RS232 between PC and amplifier.
•
Switch on the amplifier and start the
Visual Drive Setup
software on the PC, under WINDOWS
®
.
If the message
No serial communication found
is displayed on the screen, click on OK and check the following
points:
o
The amplifier must be on,
o
The correct RS232 connection between amplifier and PC,
o
The correct software configuration (
Com.port
, ...).
For the parameterization of the amplifier via the
Visual Drive Setup
software, set all DIP micro-switches at
position OFF (address 00).
7 - MOTOR ADJUSTMENT
7.1 - CONFIGURATION OF THE SENSOR TYPE
The configuration of the sensor type is software selectable and saved in the amplifier EEPROM.
The amplifier is configured as standard for a resolver sensor. For motors equipped with an encoder, please
proceed as follows:
Select the appropriate encoder type in the
Resolver & Encoder input configuration
menu.
Select
Encoder feedback
and confirm this selection.
Then enter
the
Motor encoder Resolution
value in the
Servo Motor
module.
If the motor is equipped with Hall effect sensors, check that the ENABLE input is not activated and the amplifier is
on, before moving manually the motor over one revolution or one pole pitch on linear motors. If the
HES
error is
displayed, switch off the amplifier and check the following points before switching it on again:
The Hall effect sensors (HES) must be correctly connected on the amplifier X3 connector (if 60° Hall sensor
types are used, check the various wiring combination of the HES signals for finding the right wiring order).
Check for the correct supply voltage of the Hall sensors.
Check for the correct value of the
Motor encoder Resolution
parameter.
If the motor Hall sensors do not work correctly, select the appropriate incremental encoder type (
Incremental
Encoder
without HES) in the
Feedback configuration
menu and start the amplifier commissioning with this
configuration.
If the motor used is equipped with an absolute Sin/Cos encoder over one revolution (Heidenhain ERN 1085 or
compliant), check that the ENABLE input is not activated and the amplifier on. Then move manually the motor
over one revolution. If the
HES
error is displayed, switch off the amplifier
and check the following points before
switching it on again:
The commutation channels of the Sin/Cos encoder must be correctly wired on the amplifier X3 connector.
Check for the correct supply voltage of the Sin/Cos encoder.
Check for the correct value of the
Motor encoder resolution
parameter.
Perform the
Save parameters to EEPROM
procedure before switching off the amplifier in order to save the
sensor configuration.