Introduction

This guide provides an overview of the Infoblox-4030 and Infoblox-4030-10GE caching accelerator appliances and explains how to install and
configure them. For information about which NIOS releases the Infoblox-4030 and Infoblox-4030-10GE appliances support, refer to the Read Me
First document and release notes for your product.

Product Overview

The Infoblox-4030 and Infoblox-4030-10GE are high performance network appliances for core network services, including DNS (Domain Name
System) caching. You can configure and manage the Infoblox-4030 or Infoblox-4030-10GE through an Infoblox GUI that works seamlessly in
Windows, Linux, and Mac environments using standard web browsers.
The Infoblox-4030 and Infoblox-4030-10GE appliances contain power supplies, fan modules, hard disk drives and network interfaces. They are
Class A and Class B (with limits) digital appliances per FCC regulations. For the appliances to be NEBS Level 3 compliant, ensure that you do not
install the optional front cover that ship with the appliance. For information about the front cover, see 

.

 

Hardware Components

Basic features of the Infoblox-4030 and Infoblox-4030-10GE include the following:

Support for all DNS caching, DNSSEC, Grid Management, and all administrative features for Infoblox DNS
Four (4) SFP or SFP+ Gigabit Ethernet interfaces
10-Gigabit Ethernet (Infoblox-4030-10GE only)
High Availability support
Field replaceable hard disk drives
Hot-swappable AC power supplies
Field replaceable fan modules
Optional DC power supplies

Note: There are two versions of the Infoblox-4030 appliance: Rev-1 and Rev-2. Both versions support the same NIOS features. They are different
in physical appearance and CPU speeds. This guide only contains information about the Infoblox-4030 Rev-2 appliance, referred to generically in
this Guide as the Infoblox-4030. For information about the Infoblox-4030 Rev-1 appliance, refer to the 

 

 

 

 

Infoblox Installation Guide for the Infoblox-4

 

 

.

030 Rev-1 Appliance
Identify your Infoblox-4030 version by looking at its physical appearance and the serial number; Rev-2 appliance serial numbers begin with a
4835 prefix and Rev-1 appliance serial numbers begin with a 40 prefix.

Infoblox supports the previous Infoblox-4030 platform version, Rev-1, only with field-replaceable units (FRUs) and warranty replacements. Current
Rev-2 platform FRUs, such as power supplies and fan units, are not compatible with Infoblox-4030 Rev-1 hardware and FRUs, and vice versa.
Ensure that you use the correct FRUs for your Infoblox-4030 appliance. For information about FRUs, see 

 

.

Field Replaceable Units

Hardware Components

The Infoblox-4030 and Infoblox-4030-10GE are 2-U platforms that you install in a seismic equipment rack using mounting rails and materials that
ship with each appliance. For information about rack mounting, see 

.

 

Installing

 

the

 

Infoblox-4030

 

and Infoblox-4030-10GE

The Infoblox-4030 front panel comes with an optional front cover that you can install when you first set up the appliance. For information about
how to install the front cover, refer to the installation instructions that ship with it.

Note: (DC Systems only) If you want your appliance to be NEBS Level 3 compliant, DO NOT install the front cover.

   

 

 

Figure 1 Infoblox-4030/Infoblox-4030-10GE, Front View with Cover

Front Panel

After you remove the front panel cover, front panel components include the hard disk drives and indicator lights. Front panel components are
illustrated in 

.

 

Figure 2

Содержание Infoblox-4030

Страница 1: ...Infoblox Installation Guide for Infoblox 4030 Appliances Rev2 Infoblox 4030 Appliance Infoblox 4030 10GE Appliance...

Страница 2: ...Powering On the Appliance 12 2 4 Network Connectivity 12 2 5 Cabling the Appliance to the Network 13 3 Accessing the Infoblox Appliance 13 3 1 Connecting to the Appliance 14 3 2 Auto Provisioning NIO...

Страница 3: ...ersions support the same NIOS features They are different in physical appearance and CPU speeds This guide only contains information about the Infoblox 4030 Rev 2 appliance referred to generically in...

Страница 4: ...e Fault UID LED green amber that indicates the connection of the disk drive and a circular Online Activity LED green that goes around the Fault UID LED to indicate read write activity status of the di...

Страница 5: ...lox 4030 and Infoblox 4030 10GE appliances If the appliance operates as a standalone appliance the HA port may not be used for DNS service traffic and remains inactive LAN2 Port A port that connects a...

Страница 6: ...ed Install all transceivers into the ports for your appliance before turning the system on for the first time The LAN1 and HA ports must be set to the same line speed by using the same transceivers In...

Страница 7: ...32 standard Figure 6 DB 9 Pin Assignments SFP SFP Interfaces Note In Infoblox 4030 10GE appliances always install your transceivers in the ports before turning your system on for the first time Instal...

Страница 8: ...Uncooled 1310nm DFB laser Receiver limiting electrical interface Duplex LC connector Infoblox SFP Short Range 10GbE SR fiber Transceiver Infoblox part number IB SFPPLUS SR Hot pluggable SFP footprint...

Страница 9: ...Heat Output BTU hour 2925 BTU at 100VAC 2812 BTU at 200VAC Maximum Peak Power 750 W at 100V to 240V AC input DC Power Supply 48v 750W GRND TERM RING VIN 12 10 AWG 10 Rated Input Voltage 48VDC Rated I...

Страница 10: ...ear of the rack Minimum clearance of 121 9 cm 48 in from the rack rear to the rear of another rack or row of racks The appliance draws air in through the front of the chassis and expels air through th...

Страница 11: ...g that you can safely withdraw the system from the rack without accidentally pulling it free 10 Snap the appliance into place and fasten it to the rack using the retainer screws provided in the access...

Страница 12: ...er supply modules or two hot swappable redundant DC power supply modules Infoblox recommends using the power cables shipped with the appliance to connect each power supply to separate power circuits I...

Страница 13: ...he Network Use one or more optical fiber Ethernet cables to connect the appliance to the network depending on the deployment Connect an Ethernet cable from the LAN1 port on the to the network switch o...

Страница 14: ...Hyperterminal Grid Manager fully supports Microsoft Internet Explorer 11 x and 10 x when you enable compatibility view in the browser Features in the Repor tab may not function properly if you disable...

Страница 15: ...s the Grid If the Grid member fails to join the Grid then the remote console is enabled for the appliance and you can join the appliance to the Grid through the remote console You can login to the rem...

Страница 16: ...ws you to configure and monitor the appliance using a small set of Infoblox commands Some tasks such as resetting the appliance can only be done through the CLI You can access the Infoblox CLI through...

Страница 17: ...blox field representative or Infoblox Technical Support Note Hardware and FRUs field replaceable units for Infoblox 4030 Rev 1 and Rev 2 are not compatible with each other Ensure that you order the co...

Страница 18: ...isks from the appliance at the same time Removing two or more disks at the same time may result in an appliance failure and require an RMA of the appliance This rule applies to both powered and powere...

Страница 19: ...a 1 1 configuration The power supplies are hot swappable so you can remove or replace one power supply without interrupting appliance operation and network services When a power supply fails for any...

Страница 20: ...all ation or replacement steps or maintenance of the power supply In DC power configuration the Infoblox 4030 and Infoblox 4030 10GE appliances ship with two redundant auto switching DC power supplies...

Страница 21: ...on DC Systems Only Important Retain your original AC power supplies for possible future RMAs When you remove the AC power supplies for new DC power supplies ensure that you keep the original AC power...

Страница 22: ...on the top of each fan module which you grasp with fingertips when pulling the unit out of the system Pay attention to unit alignment and placement before removing from the system Figure 17 System fan...

Страница 23: ...lists the Ethernet SFP Table 10 transceivers that are compatible with Infoblox Ethernet SFP SFP interfaces and basic guidelines for compatibility Table 10 Transceivers for 1GbE SFP and 10GbE SFP Supp...