Copyright ©2018, Infoblox, Inc.All right reserved.
5. Slide the top panel off and visually inspect the fans to determine which unit has stopped spinning and must be replaced.
6.
Figure 17
shows a four-fan-module configuration. The system fans can be removed from their installation base and replaced. A pair of
small handles reside on the top of each fan module, which you grasp with fingertips when pulling the unit out of the system. Pay attention to
unit alignment and placement before removing from the system.
Figure 17 System fan assembly for Infoblox-4030/Infoblox-4030-10GE; pull gently on top of the failed fan unit. Each unit is numbered.
7. Place the new fan in the system. Note that the fans can be installed correctly in only one direction, as shown in
.
Figure 18
Figure 18 Fan blades point towards rear of chassis for Infoblox-4030/Infoblox-4030-10GE
Содержание Infoblox-4030