mount the appliance to a seismic rack, you also need the following:

M5 rack screws that fit the seismic rack
Round-hole M5 cage nuts for use with the seismic rack
A screwdriver

SFP/SFP+ Transceiver Installation and Removal Guidelines

After receiving a shipped Infoblox appliance appliance with SFP or SFP+ support, Infoblox recommends installing the transceivers into your
appliance before turning power on to the system for the first time. (This procedure is required for the Infoblox-4030-10GE appliance.) Pay heed to
the interface configuration required for your application (for related information, see 

).

 

 

10-Gigabit Ethernet Connectivity

Should circumstances require you to ship an appliance to Infoblox for repair or replacement, 

 

 

   

 

 

 

 

remove all SFP or SFP+ transceivers from your appli

 

 

   

   

. Keep your transceivers in your facility until the appliance is replaced or repaired and subsequently

ance before shipping it back to Infoblox
returned to you.

Rack Mounting Safety Requirements

The following space and airflow requirements are required for Infoblox-4030 and Infoblox-4030-10GE system operation:

Minimum clearance of 63.5 cm (25 in) in front of the rack
Minimum clearance of 76.2cm (30 in) in the rear of the rack
Minimum clearance of 121.9 cm (48 in) from the rack rear to the rear of another rack or row of racks

The appliance draws air in through the front of the chassis and expels air through the rear. Adequate ventilation is required to allow ambient room
air to enter the system chassis and to be expelled from the rear of the chassis.
To mount the appliance to a seismic rack, do the following:

Unscrew the snap-in screws from the mounting rails and discard.
Install the round-hole M5 cage nuts in the appropriate rack hole positions where you want to install the appliance. Ensure that you install
two cage nuts on the front and two on the back of each rail, as shown in 

. Note that the square-hole cage nuts that ship with the

Figure 7

accessory kit do not fit in the seismic rack.

   

 

 

 

Figure 7 Installing the Round-Hole M5 Cage Nuts

3. Line up a mounting rail with cage nuts, and attach the mounting rail to the rack with M5 screws. Ensure that the front end of each
mounting rail connects to the front of the rack.

Note: Ensure that both rail assemblies are correctly leveled.

4. Repeat steps 1 to 3 for the other mounting rail.

5. Slide out the side rails from each mounting rail and press the flange that holds each side rail in place. Then pull out each of the side rails
from the assembly.

Note: Make sure that you keep track of the front end of each rail.

6. Align each side rail to the appliance and snap them in place, as shown in 

.

 

Figure 8

Содержание Infoblox-4030

Страница 1: ...Infoblox Installation Guide for Infoblox 4030 Appliances Rev2 Infoblox 4030 Appliance Infoblox 4030 10GE Appliance...

Страница 2: ...Powering On the Appliance 12 2 4 Network Connectivity 12 2 5 Cabling the Appliance to the Network 13 3 Accessing the Infoblox Appliance 13 3 1 Connecting to the Appliance 14 3 2 Auto Provisioning NIO...

Страница 3: ...ersions support the same NIOS features They are different in physical appearance and CPU speeds This guide only contains information about the Infoblox 4030 Rev 2 appliance referred to generically in...

Страница 4: ...e Fault UID LED green amber that indicates the connection of the disk drive and a circular Online Activity LED green that goes around the Fault UID LED to indicate read write activity status of the di...

Страница 5: ...lox 4030 and Infoblox 4030 10GE appliances If the appliance operates as a standalone appliance the HA port may not be used for DNS service traffic and remains inactive LAN2 Port A port that connects a...

Страница 6: ...ed Install all transceivers into the ports for your appliance before turning the system on for the first time The LAN1 and HA ports must be set to the same line speed by using the same transceivers In...

Страница 7: ...32 standard Figure 6 DB 9 Pin Assignments SFP SFP Interfaces Note In Infoblox 4030 10GE appliances always install your transceivers in the ports before turning your system on for the first time Instal...

Страница 8: ...Uncooled 1310nm DFB laser Receiver limiting electrical interface Duplex LC connector Infoblox SFP Short Range 10GbE SR fiber Transceiver Infoblox part number IB SFPPLUS SR Hot pluggable SFP footprint...

Страница 9: ...Heat Output BTU hour 2925 BTU at 100VAC 2812 BTU at 200VAC Maximum Peak Power 750 W at 100V to 240V AC input DC Power Supply 48v 750W GRND TERM RING VIN 12 10 AWG 10 Rated Input Voltage 48VDC Rated I...

Страница 10: ...ear of the rack Minimum clearance of 121 9 cm 48 in from the rack rear to the rear of another rack or row of racks The appliance draws air in through the front of the chassis and expels air through th...

Страница 11: ...g that you can safely withdraw the system from the rack without accidentally pulling it free 10 Snap the appliance into place and fasten it to the rack using the retainer screws provided in the access...

Страница 12: ...er supply modules or two hot swappable redundant DC power supply modules Infoblox recommends using the power cables shipped with the appliance to connect each power supply to separate power circuits I...

Страница 13: ...he Network Use one or more optical fiber Ethernet cables to connect the appliance to the network depending on the deployment Connect an Ethernet cable from the LAN1 port on the to the network switch o...

Страница 14: ...Hyperterminal Grid Manager fully supports Microsoft Internet Explorer 11 x and 10 x when you enable compatibility view in the browser Features in the Repor tab may not function properly if you disable...

Страница 15: ...s the Grid If the Grid member fails to join the Grid then the remote console is enabled for the appliance and you can join the appliance to the Grid through the remote console You can login to the rem...

Страница 16: ...ws you to configure and monitor the appliance using a small set of Infoblox commands Some tasks such as resetting the appliance can only be done through the CLI You can access the Infoblox CLI through...

Страница 17: ...blox field representative or Infoblox Technical Support Note Hardware and FRUs field replaceable units for Infoblox 4030 Rev 1 and Rev 2 are not compatible with each other Ensure that you order the co...

Страница 18: ...isks from the appliance at the same time Removing two or more disks at the same time may result in an appliance failure and require an RMA of the appliance This rule applies to both powered and powere...

Страница 19: ...a 1 1 configuration The power supplies are hot swappable so you can remove or replace one power supply without interrupting appliance operation and network services When a power supply fails for any...

Страница 20: ...all ation or replacement steps or maintenance of the power supply In DC power configuration the Infoblox 4030 and Infoblox 4030 10GE appliances ship with two redundant auto switching DC power supplies...

Страница 21: ...on DC Systems Only Important Retain your original AC power supplies for possible future RMAs When you remove the AC power supplies for new DC power supplies ensure that you keep the original AC power...

Страница 22: ...on the top of each fan module which you grasp with fingertips when pulling the unit out of the system Pay attention to unit alignment and placement before removing from the system Figure 17 System fan...

Страница 23: ...lists the Ethernet SFP Table 10 transceivers that are compatible with Infoblox Ethernet SFP SFP interfaces and basic guidelines for compatibility Table 10 Transceivers for 1GbE SFP and 10GbE SFP Supp...

Страница 24: ...Copyright 2018 Infoblox Inc All right reserved...

Отзывы: