background image

Copyright ©2018, Infoblox, Inc.All right reserved.

1.  

Hard Disk Replacement

Use the following procedure to remove a spinning disk:

Press the red button on the disk drive, unlatch and pull the disk about two cm (one inch) to disengage contact, as indicated in 

.

 

Figure 13

 

 

   

 

 

 

 

 

Figure 13 Pull disk latch to remove hard drive for Infoblox-4030/Infoblox-4030-10GE

2. Wait about 30 seconds for the disk to completely stop spinning.

3. Remove the disk, extract it from its carrier and handle it with care. Do not drop the disk or ship it loosely in a carton.

4. Securely mount the replacement disk in the drive carrier and replace the carrier in the system.

Changing AC Power Supplies

Note: Before changing power supplies, make sure that they are securely cabled. An apparently failed power supply may simply be improperly
connected to its power source.

The Infoblox-4030 and Infoblox-4030-10GE appliances ship with two redundant, auto-switching AC power supplies or optional DC power supplies,
in a 1+1 configuration. The power supplies are "hot-swappable", so you can remove or replace one power supply without interrupting appliance
operation and network services.
When a power supply fails for any reason, NIOS displays a power supply alarm. The Infoblox NIOS Dashboard will also display an Error under
Grid Status. An email notification will be sent and an SNMP Trap will be reported.
When the appliance contains two functioning power supplies, they share the power load. If one power supply fails, the other assumes the full load
automatically and the appliance sends the system alarm to NIOS. Although the appliance can run with only one power supply, Infoblox
recommends installing both power supplies that are shipped with the appliance. This configuration minimizes the chance of system failure due to
failure of an individual power supply. 
Each power supply weighs about three pounds (1.36 kg). The faceplate of the power supply contains a power LED and a power switch. Each AC
power supply provides a dedicated male power outlet. 

 illustrates the process of replacing an AC power supply.

Figure 14

 

 

 

Figure 14 Removing an Infoblox-4030/Infoblox-4030-10GE AC Power Supply

Содержание Infoblox-4030

Страница 1: ...Infoblox Installation Guide for Infoblox 4030 Appliances Rev2 Infoblox 4030 Appliance Infoblox 4030 10GE Appliance...

Страница 2: ...Powering On the Appliance 12 2 4 Network Connectivity 12 2 5 Cabling the Appliance to the Network 13 3 Accessing the Infoblox Appliance 13 3 1 Connecting to the Appliance 14 3 2 Auto Provisioning NIO...

Страница 3: ...ersions support the same NIOS features They are different in physical appearance and CPU speeds This guide only contains information about the Infoblox 4030 Rev 2 appliance referred to generically in...

Страница 4: ...e Fault UID LED green amber that indicates the connection of the disk drive and a circular Online Activity LED green that goes around the Fault UID LED to indicate read write activity status of the di...

Страница 5: ...lox 4030 and Infoblox 4030 10GE appliances If the appliance operates as a standalone appliance the HA port may not be used for DNS service traffic and remains inactive LAN2 Port A port that connects a...

Страница 6: ...ed Install all transceivers into the ports for your appliance before turning the system on for the first time The LAN1 and HA ports must be set to the same line speed by using the same transceivers In...

Страница 7: ...32 standard Figure 6 DB 9 Pin Assignments SFP SFP Interfaces Note In Infoblox 4030 10GE appliances always install your transceivers in the ports before turning your system on for the first time Instal...

Страница 8: ...Uncooled 1310nm DFB laser Receiver limiting electrical interface Duplex LC connector Infoblox SFP Short Range 10GbE SR fiber Transceiver Infoblox part number IB SFPPLUS SR Hot pluggable SFP footprint...

Страница 9: ...Heat Output BTU hour 2925 BTU at 100VAC 2812 BTU at 200VAC Maximum Peak Power 750 W at 100V to 240V AC input DC Power Supply 48v 750W GRND TERM RING VIN 12 10 AWG 10 Rated Input Voltage 48VDC Rated I...

Страница 10: ...ear of the rack Minimum clearance of 121 9 cm 48 in from the rack rear to the rear of another rack or row of racks The appliance draws air in through the front of the chassis and expels air through th...

Страница 11: ...g that you can safely withdraw the system from the rack without accidentally pulling it free 10 Snap the appliance into place and fasten it to the rack using the retainer screws provided in the access...

Страница 12: ...er supply modules or two hot swappable redundant DC power supply modules Infoblox recommends using the power cables shipped with the appliance to connect each power supply to separate power circuits I...

Страница 13: ...he Network Use one or more optical fiber Ethernet cables to connect the appliance to the network depending on the deployment Connect an Ethernet cable from the LAN1 port on the to the network switch o...

Страница 14: ...Hyperterminal Grid Manager fully supports Microsoft Internet Explorer 11 x and 10 x when you enable compatibility view in the browser Features in the Repor tab may not function properly if you disable...

Страница 15: ...s the Grid If the Grid member fails to join the Grid then the remote console is enabled for the appliance and you can join the appliance to the Grid through the remote console You can login to the rem...

Страница 16: ...ws you to configure and monitor the appliance using a small set of Infoblox commands Some tasks such as resetting the appliance can only be done through the CLI You can access the Infoblox CLI through...

Страница 17: ...blox field representative or Infoblox Technical Support Note Hardware and FRUs field replaceable units for Infoblox 4030 Rev 1 and Rev 2 are not compatible with each other Ensure that you order the co...

Страница 18: ...isks from the appliance at the same time Removing two or more disks at the same time may result in an appliance failure and require an RMA of the appliance This rule applies to both powered and powere...

Страница 19: ...a 1 1 configuration The power supplies are hot swappable so you can remove or replace one power supply without interrupting appliance operation and network services When a power supply fails for any...

Страница 20: ...all ation or replacement steps or maintenance of the power supply In DC power configuration the Infoblox 4030 and Infoblox 4030 10GE appliances ship with two redundant auto switching DC power supplies...

Страница 21: ...on DC Systems Only Important Retain your original AC power supplies for possible future RMAs When you remove the AC power supplies for new DC power supplies ensure that you keep the original AC power...

Страница 22: ...on the top of each fan module which you grasp with fingertips when pulling the unit out of the system Pay attention to unit alignment and placement before removing from the system Figure 17 System fan...

Страница 23: ...lists the Ethernet SFP Table 10 transceivers that are compatible with Infoblox Ethernet SFP SFP interfaces and basic guidelines for compatibility Table 10 Transceivers for 1GbE SFP and 10GbE SFP Supp...

Страница 24: ...Copyright 2018 Infoblox Inc All right reserved...

Отзывы: