background image

LT 6541 (Iss 4 07/14) 

 

INFINITY 890 BF 

Users Instructions 

SECTION THREE 

Operation Cont.

 

 
e.  The appliance can be switched off with out using the hand set by removing the appliance batteries 

located  behind  the  fascia.  When  the  batteries  are  removed  there  will  be  a  delay  (up  3minutes) 
after  which,  double  bleeps  may  be  heard  and  shortly  after  the  appliance  will  extinguish.  Ensure 
that  the  battery  is  reconnected  once  the  fire  as  been  extinguished.  The  appliance  cannot  be 
operated without the use of the handset. 

Room Thermostat mode 

The remote handset checks the room temperature at a fixed time intervals. Depending on the 
difference between set room temperature and the actual room temperature the remote proceeds to 
modulate in one level steps. Once the room temperature is reached it moves to standby position pilot 
only. 

 

The icon “PILOT” will appear on the LCD display. As soon as the actual room temperature falls below 
the SET room temperature, the system will move from standby to the high flame level. From this point 
it will proceed again the modulation process.  

Note: Due to the temperature checks at timed intervals, the display temperature on the handset may exceed 
the room setting temperature before the appliance defaults to the pilot setting

 

TO REPLACE BATTERY IN HAND SET (3 AAA TYPE BATTERIES) 

Remove the cover from the rear of the handset and fit replacement battery. 

 
Clock Regulation 

 As soon as the batteries are fitted the timer digits will blink.  Using the 

 arrow 

key increase or decrease the hour, minutes and week`s value. By pressing the 

O

 will set and shift setting until complete. 

 

Changing Clock Setting During Operation 

To amend timer setting press both the 

 and 

keys simultaneously for three seconds, the written 

clock will appear.  To change the clock settings, repeat the above described operation. 
 

Change From Celsius to Fahrenheit  

With  remote  OFF,  keeping  pressed 

key  at  least  for  5  seconds,  the  temperature  unit  changes 

from Celsius to Fahrenheit degrees and vice versa. 
 

Battery level indication (Handset) 

When the batteries have to be changed in the handset, the related icon will appear. 
 

 
Setting the sleep mode   
 

To  activate  the  sleep  mode:

 

With  the  fire  switched  on  press  the 

button.  The  sleep  symbol                              

will  appear  top  right          .  The  sleep  symbol  replaces  the  time  indicator  in  this  mode.  Using  the 

 

arrow key increase the sleep mode in 15 minute intervals (a small star will be visible next to the sleep 

symbol  once  any  time  is  set)

  .Once  the  set  time  is  reached,  the  fire  will  completely  switch  off 

without any further intervention. 
 
 

Содержание 890 BF

Страница 1: ...GAS FIRE OWNER S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is For use in GREAT BRITAIN or IRELAN...

Страница 2: ...SEVEN Siting the Appliance 14 General Requirements 15 SECTION EIGHT Preparing the Appliance for Installation 15 SECTION NINE Install the appliance 17 Installing the Appliance into a Cavity Wall 17 Ins...

Страница 3: ...If a vacuum is used for cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep...

Страница 4: ...should be used for the protection of children the elderly or infirm Fireguards should conform to B S 6539 1984 Fireguards for use with solid fuel appliance Care should be taken to prevent any damage...

Страница 5: ...remote control hand set in the direction of the appliance and press the button Continue to hold the button for approximately 2 seconds and release When released a bleep should be and heard the applia...

Страница 6: ...the room setting temperature before the appliance defaults to the pilot setting TO REPLACE BATTERY IN HAND SET 3 AAA TYPE BATTERIES Remove the cover from the rear of the handset and fit replacement ba...

Страница 7: ...sed when the battery is completely discharged TO REPLACE APPLIANCE BATTERIES 6 High Power Alkaline C 1 5V a Remove the trim held in place with magnets b Remove the battery holder from within the prote...

Страница 8: ...e the appliance has been used for a long period without glass panel being cleaned use a new Brillo Pad well wetted with the Hob cleaner applied directly to it Ensure all the residues of the cleaner ar...

Страница 9: ...fitted at the rear and held in place with two M4 x 10mm screws at either end Place to Burner Bar Edge Cover over the front of the Burner Bar with the slot at the left hand side so it covers the edge P...

Страница 10: ...apes on top of the Air Bridge as far back to the rear as possible as shown in the picture and space them evenly Place the next Two large shapes and One small shape as shown making sure they do not mov...

Страница 11: ...OUR Cleaning Laying the fuel bed Continued Log Fuel Bed Layout Position the Smallest Log shape as shown in picture Place the next Two Middle shapes as shown resting on the rear shapes making sure they...

Страница 12: ...the pilot flame The last small shape goes across the Burner and the Burner End Plate as far forward as possible to keep it out of the pilot flame as much as possible the small shape is for decorative...

Страница 13: ...w Gas Connection 8 0mm O D tube Data Badge Location On bottom right hand side of fire box under batteries MODEL Natural Gas G20 Version Category of appliance CII NOX Class 5 Efficiency Class 1 Gas Cat...

Страница 14: ...be installed to current versions of the above standards and include any relevant amendments The Building Regulations issued by The Department of the Environment The Building Standards Scotland Consol...

Страница 15: ...ir duct must not have any bends The flue outlet must terminate on a suitable outside wall The minimum flue terminal clearances which must be maintained are as shown below A Directly below an openable...

Страница 16: ...shelf chart Check with the supplier or manufacturer that the surround meets 1500 C minimum rating attention should especially be given to man made materials such as resin When installing in a timber...

Страница 17: ...al line for a height of 430mm If insetting into the wall mark the position for a lintel above the top horizontal line Mark a short horizontal line so it crosses the centre line at 75mm above hearth le...

Страница 18: ...the opening and position the gas supply see connecting the gas supply later in this manual taking account of the relative gas regulations regarding a gas pipe in a cavity sleeving and sealing etc Not...

Страница 19: ...y be present if the rear of the appliance is contacting the wall i e ensure no battens etc behind dry lining in the area shown around the flue and top of firebox Always remove a 25mm 1 area around the...

Страница 20: ...he inner timber leaf must also be located and taken into account when positioning the appliance The following methods of installation may be adapted for use in timber frame buildings providing extra c...

Страница 21: ...CHECKING GAS SOUNDNESS Complete gas connection to the fire and check for gas soundness in accordance with current codes of practice SECTION TEN Assemble the Appliance Position the shaped components a...

Страница 22: ...due to the curing of the paint the appliance should be operated on its high setting and it is recommended that a window is left open until that odour has completely disappeared Instruct on the glass...

Страница 23: ...this manual 3 Remove all shapes remove the Burner Bar Edge Cover 4 Remove the two Burner End Plates 2 6 x 3 8 screws in each and Air Bridge 2 x M4 x 10mm screws in each corner 5 Remove the Black Line...

Страница 24: ...ipe gently back taking care not to damage pipe or olive hook nut 4 Remove the pilot injector from inside the pilot bracket 5 Clean or replace pilot injector Replacement of the EDB Unit 1 Remove the M3...

Страница 25: ...ust be installed by a GAS SAFE registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a GAS SAFE registered person 4 The...

Страница 26: ...the helpdesk Model INFINITY 890 BF Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the base of the appliance behind the control...

Страница 27: ...rst annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration No Date...

Страница 28: ...LT 6541 Iss 4 07 14 28...

Страница 29: ...ETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model INFINITY 890 BF Serial No Date of Purchase This information can be fo...

Страница 30: ...LT 6541 Iss 4 07 14 30...

Страница 31: ...LT 6541 Iss 4 07 14 31...

Страница 32: ...406 Glass Sub Assembly Silicone Sealing Strip 4818 Linings Side rear and top AAA Batteries 3 Remote Control Hand Set C Batteries 12 Handset Holder 5910 Battery Holder Log Set Complete Flue Terminal Ki...

Отзывы: