Appliance Data
Fire Box dimensions:
Height
456mm
Width
970mm
Forward Projection:
10mm
Overall Trim
dimensions………………………………….Height 462mm
Width 1054mm
Trim Forward dimensions………………………………………………..23mm
Weight:
35kg
Flue Len
gth………………………………………...100mm (minimum) to 1000mm (maximum)
Standard length supplied with fire 535mm(267.5mm
after cutting). Additional 535mm or 1000mm tubes
supplied as optional extras.(No bends or joined flue
pipes should be used in the flue system).
Pressure Test Point Location:
Gas inlet elbow
Gas Connection:
8.0mm O/D, tube.
Data Badge Location:
On bottom right hand side of fire box under batteries.
MODEL
Natural Gas (G20) Version
Category of appliance
C
II
NO
X
Class
5
Efficiency Class
1
Gas Category
I
2H
Gas Type
G20 Natural Gas
Gas Pr/- 1.0mbar
20 mbar
Gas Input (Max)
3.4 KW Gross
(Min)
1.6 kW Gross
Injectors size
220A Mark
NOTE: The efficiency of this appliance has been measured as specified in BS EN613-2001 and the
result is 82.1% natural gas. The gross calorific value of the fuel has been used for this efficiency
calculation. Gastec have certified the test data from which it has been calculated. The efficiency
value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating
of dwellings.