LT 6541 (Iss 4 07/14)
3
INFINITY 890 BF
Users Instructions
SECTION ONE
Important Information
Consumer Protection Information
As manufacturers and suppliers of heating products, we take every care, as far as is reasonably
practicable, that these products are so designed and constructed as to meet the general safety
requirement when properly used and installed. To this end, our products are thoroughly tested and
examined before despatch.
IMPORTANT NOTICE:
Any alteration that is not approved by the appliance manufacturer could
invalidate the approval of the appliance, operation of the warranty and could affect your statutory
rights.
Health and Safety Notice
Important
This appliance could contain some of the materials, indicated below, that could be interpreted as
being injurious to health and safety. It is the users / installers responsibility to ensure that the
necessary personal protective clothing is worn when handling these materials, see below for
information.
Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic Fibres, Glass Yarn -
may
be harmful if inhaled, may be irritating to skin, eyes, nose and throat.
When handling
avoid inhaling and contact with skin or eyes. Use disposable gloves, facemasks
and eye protection. After handling wash hands and other exposed parts. If a vacuum is used for
cleaning the coals or cleaning after servicing / installation it is recommended that it be of the type
fitted with a HEPA filter.
Disposal of refractory/ceramic materials
.
To keep dust to a minimum these materials
should be securely wrapped in polythene and be clearly labelled ‘RCF waste’. These materials are
not classified as ‘hazardous waste’ and should be disposed of at a site licensed for the disposal of
industrial waste.
INTRODUCTION
The INFINITY 890 BF is an inset room sealed decorative fuel-effect gas appliance.
The INFINITY 890 BF is available in
Natural Gas only.
The INFINITY 890 BF
must not
be installed into a natural draught flue or chimney.
The INFINITY 890 BF should only be installed and serviced by a competent person i.e. GAS
SAFE registered, in accordance with the GAS SAFETY (INSTALLATION AND USE)
REGULATIONS.
The INFINITY 890 BF does not require a chimney, but
must be
installed against an outside wall.
It is important that the flue terminal is regularly checked and kept clear at all times.
If the terminal is accessible to people (i.e. less than 2m above a walkway, balcony etc.) the
terminal guard must be fitted to prevent access to the flue outlet, which becomes hot when the fire
is in use.
As the INFINITY 890 BF is a room sealed appliance (i.e. air for the combustion process is taken
from outside the room) no purpose built ventilation is required.
The INFINITY 890 BF is designed and tested to meet the requirements of the European Standard
EN 613.