Introduction

 

 

 

The  INFINITY  890  BF  is  an  inset  room  sealed decorative fuel-effect  gas  appliance designed for 
use in locations that do not have a conventional chimney. The appliance must be installed against 
an outside wall because the air to support combustion is taken from the outside and the products 
of combustion are expelled to the outside. 

 

 

The  appliance  incorporates  a  safety  device  in  the  form  of  a  FLAME  SUPERVISION  DEVICE, 
which  constantly  monitors  the  flame  and  will  cause  the  gas  to  be  switched  off  if  the  flames  are 
extinguished  for  any  reason.

  THIS  DEVICE  MUST  NOT  BE  OVERRIDDEN. 

If  this  situation 

occurs on a regular basis have the appliance checked by a qualified engineer. The problem may 
be due to a blocked or restricted flue.

 

 

Before removing the, trim, glass  shapes for cleaning the fire should be turned off, and left to cool 
down.

 

 

NOTE:

 In use some discoloration of the components will take place in the combustion box, this is 

normal, but can be kept to a minimum if the shapes are placed correctly (i.e. after cleaning). See 
Section 4. 

 

As  with  all  heating  appliances  certain  areas  (Working  Surfaces)  become  very  hot  when  the 
appliance is in use. 

 

 

SECTION THREE 

Operation

 

 

To light the appliance using the remote hand set:

 

a.  Point  the  remote  control  hand  set  in  the  direction  of 

the  appliance  and  press  the 

  button.  Continue  to 

hold  the  button  for  approximately  2  seconds  and 
release. When released a bleep should be and heard 
the appliance will automatically go through the ignition 
sequence and the pilot should ignite. Once the pilot is 
alight  the  appliance  will  automatically  go  to  the  high 
setting (approximately 20-25sec).  

b.  If  the  ignitor  stops  sparking  and  the  pilot  fails  to  light 

press  the 

  button  for  at  least  2  seconds  and 

release,  again  a  bleep  should  be  heard.  Then  repeat 
the lighting procedure.

* See note on page 7

 

c.  With the appliance lit, by pressing 

 key the operational mode is switched from manual to Room 

thermostat setting and vice versa. When Room thermostat mode is active, the display shows the 

set temperature value and the “AUTO” icon will appear on the LCD display. By using the

  arrow 

key the desired room temperature can be set.  When manual mode is active, the display shows 

the “MAN” icon plus the flame icon and a five level bar icon setting. By pressing the 

 arrow key, 

the flame picture can be adjusted at five stages between high and low flame. If level 5 is currently 

active, the icon max  

 below the flame icon will appear.    

d.  To switch off the appliance press the 

 button for at least 2 seconds and on releasing the button 

the appliance will bleep and then shut off. For pilot setting press the 

 for 1 second and release. 

The  pilot  symbol  will  appear  on  the  LCD  display.Pressing  the 

button  will  bring  the  fire  back 

onto main flame. 

Содержание 890 BF

Страница 1: ...GAS FIRE OWNER S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is For use in GREAT BRITAIN or IRELAN...

Страница 2: ...SEVEN Siting the Appliance 14 General Requirements 15 SECTION EIGHT Preparing the Appliance for Installation 15 SECTION NINE Install the appliance 17 Installing the Appliance into a Cavity Wall 17 Ins...

Страница 3: ...If a vacuum is used for cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep...

Страница 4: ...should be used for the protection of children the elderly or infirm Fireguards should conform to B S 6539 1984 Fireguards for use with solid fuel appliance Care should be taken to prevent any damage...

Страница 5: ...remote control hand set in the direction of the appliance and press the button Continue to hold the button for approximately 2 seconds and release When released a bleep should be and heard the applia...

Страница 6: ...the room setting temperature before the appliance defaults to the pilot setting TO REPLACE BATTERY IN HAND SET 3 AAA TYPE BATTERIES Remove the cover from the rear of the handset and fit replacement ba...

Страница 7: ...sed when the battery is completely discharged TO REPLACE APPLIANCE BATTERIES 6 High Power Alkaline C 1 5V a Remove the trim held in place with magnets b Remove the battery holder from within the prote...

Страница 8: ...e the appliance has been used for a long period without glass panel being cleaned use a new Brillo Pad well wetted with the Hob cleaner applied directly to it Ensure all the residues of the cleaner ar...

Страница 9: ...fitted at the rear and held in place with two M4 x 10mm screws at either end Place to Burner Bar Edge Cover over the front of the Burner Bar with the slot at the left hand side so it covers the edge P...

Страница 10: ...apes on top of the Air Bridge as far back to the rear as possible as shown in the picture and space them evenly Place the next Two large shapes and One small shape as shown making sure they do not mov...

Страница 11: ...OUR Cleaning Laying the fuel bed Continued Log Fuel Bed Layout Position the Smallest Log shape as shown in picture Place the next Two Middle shapes as shown resting on the rear shapes making sure they...

Страница 12: ...the pilot flame The last small shape goes across the Burner and the Burner End Plate as far forward as possible to keep it out of the pilot flame as much as possible the small shape is for decorative...

Страница 13: ...w Gas Connection 8 0mm O D tube Data Badge Location On bottom right hand side of fire box under batteries MODEL Natural Gas G20 Version Category of appliance CII NOX Class 5 Efficiency Class 1 Gas Cat...

Страница 14: ...be installed to current versions of the above standards and include any relevant amendments The Building Regulations issued by The Department of the Environment The Building Standards Scotland Consol...

Страница 15: ...ir duct must not have any bends The flue outlet must terminate on a suitable outside wall The minimum flue terminal clearances which must be maintained are as shown below A Directly below an openable...

Страница 16: ...shelf chart Check with the supplier or manufacturer that the surround meets 1500 C minimum rating attention should especially be given to man made materials such as resin When installing in a timber...

Страница 17: ...al line for a height of 430mm If insetting into the wall mark the position for a lintel above the top horizontal line Mark a short horizontal line so it crosses the centre line at 75mm above hearth le...

Страница 18: ...the opening and position the gas supply see connecting the gas supply later in this manual taking account of the relative gas regulations regarding a gas pipe in a cavity sleeving and sealing etc Not...

Страница 19: ...y be present if the rear of the appliance is contacting the wall i e ensure no battens etc behind dry lining in the area shown around the flue and top of firebox Always remove a 25mm 1 area around the...

Страница 20: ...he inner timber leaf must also be located and taken into account when positioning the appliance The following methods of installation may be adapted for use in timber frame buildings providing extra c...

Страница 21: ...CHECKING GAS SOUNDNESS Complete gas connection to the fire and check for gas soundness in accordance with current codes of practice SECTION TEN Assemble the Appliance Position the shaped components a...

Страница 22: ...due to the curing of the paint the appliance should be operated on its high setting and it is recommended that a window is left open until that odour has completely disappeared Instruct on the glass...

Страница 23: ...this manual 3 Remove all shapes remove the Burner Bar Edge Cover 4 Remove the two Burner End Plates 2 6 x 3 8 screws in each and Air Bridge 2 x M4 x 10mm screws in each corner 5 Remove the Black Line...

Страница 24: ...ipe gently back taking care not to damage pipe or olive hook nut 4 Remove the pilot injector from inside the pilot bracket 5 Clean or replace pilot injector Replacement of the EDB Unit 1 Remove the M3...

Страница 25: ...ust be installed by a GAS SAFE registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a GAS SAFE registered person 4 The...

Страница 26: ...the helpdesk Model INFINITY 890 BF Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the base of the appliance behind the control...

Страница 27: ...rst annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration No Date...

Страница 28: ...LT 6541 Iss 4 07 14 28...

Страница 29: ...ETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model INFINITY 890 BF Serial No Date of Purchase This information can be fo...

Страница 30: ...LT 6541 Iss 4 07 14 30...

Страница 31: ...LT 6541 Iss 4 07 14 31...

Страница 32: ...406 Glass Sub Assembly Silicone Sealing Strip 4818 Linings Side rear and top AAA Batteries 3 Remote Control Hand Set C Batteries 12 Handset Holder 5910 Battery Holder Log Set Complete Flue Terminal Ki...

Отзывы: