AP08056
Power Saving Features
Reducing Clock Speed (Slow-Down Mode)
Application Note
10
V1.0, 2006-12
Figure 2
Graphical representation of the X and Y series in
Table 4
Current comparison between slow-down mode and slow-down-idle
mode of a XC866-4FR device
f
SYS
= 79.84 MHz
Current (mA)
Peripheral
1)
Frequency (MHz)
1) Peripheral frequency = f
SYS
/CLKREL/Fixed divider of 3 (refer to user’s manual on Clock System)
CLKREL
Slow-Down
(X)
Slow-Down-
Idle (Y)
Difference
2)
X - Y
2) Negative value indicates that slow-down-idle mode current > slow-down mode current.
26.613
0000
B
17.84
14.16
3.68
6.653
0010
B
8.62
7.70
0.92
1.663
0100
B
6.19
6.02
0.17
0.832
0101
B
5.78
5.75
0.03
0.416
0110
B
5.58
5.60
-0.02
0.208
0111
B
5.48
5.53
-0.05
0.104
1000
B
5.43
5.50
-0.07
0.052
1001
B
5.40
5.48
-0.08
0.026
1010
B
5.39
5.47
-0.08
0.013
1011
B
5.38
5.47
-0.09
0
2
4
6
8
10
12
14
16
18
20
26.613
6.653
1.663
0.832
0.416
0.208
0.104
0.052
0.026
0.013
Pe r ip h e r al Clo ck Fr e q u e n cy (M Hz ) - XC 866
Cu
rr
en
t (
m
A)
X
Y