AP08056
Power Saving Features
A Timer 2 Example
Application Note
25
V1.0, 2006-12
The current consumed by the devices were even lower than those measured in
and
. This is because the system frequency is much lower in prescaler mode
than in PLL mode.
Table 18
Current consumed by XC866-4FR device when timer 2 is active
f
SYS
= 4.99 MHz
Current (mA)
Peripheral
Frequency (KHz)
CLKREL
Slow-Down
(X)
Slow-Down-
Idle (Y)
Difference
X - Y
1663.33
0000
B
3.58
3.40
0.18
831.67
0001
B
3.17
3.13
0.04
415.83
0010
B
2.95
2.98
-0.03
103.96
0100
B
2.78
2.87
-0.09
51.98
0101
B
2.76
2.85
-0.09
25.99
0110
B
2.74
2.84
-0.10
12.99
0111
B
2.73
2.83
-0.10
Table 19
Current consumed by XC888 device when timer 2 is active
f
SYS
= 4.825 MHz
Current (mA)
Peripheral
Frequency (KHz)
CLKREL
Slow-Down
(X)
Slow-Down-
Idle (Y)
Difference
X - Y
1206.25
0000
B
4.11
3.60
0.51
603.13
0010
B
3.55
3.23
0.32
301.56
0100
B
3.26
3.04
0.22
150.78
0110
B
3.12
2.95
0.17
100.52
0111
B
3.08
2.92
0.16
75.39
1000
B
3.05
2.90
0.15
37.70
1010
B
3.02
2.89
0.13
18.85
1100
B
3.00
2.88
0.12