AP08056
Power Saving Features
Reducing Clock Speed (Slow-Down Mode)
Application Note
11
V1.0, 2006-12
Figure 3
Graphical representation of the X and Y series in
Table 5
Current comparison between slow-down mode and slow-down-idle
mode of a XC886 device
f
SYS
= 97.50 MHz
Current (mA)
Peripheral
1)
Frequency (MHz)
1) Peripheral frequency = f
SYS
/CLKREL/Fixed divider of 2 (refer to user’s manual on Clock System)
CLKREL
Slow-Down
(X)
Slow-Down-
Idle (Y)
Difference
X - Y
24.375
0000
B
23.46
20.02
3.44
12.188
0010
B
14.87
13.05
1.82
6.0941
0100
B
10.43
9.45
0.98
3.047
0110
B
8.19
7.65
0.54
1.523
1000
B
7.07
6.74
0.33
0.762
1010
B
6.50
6.29
0.21
0.381
1100
B
6.22
6.06
0.16
0.190
1110
B
6.08
5.95
0.13
0.127
1111
B
6.03
5.91
0.12
0
5
10
15
20
25
24.375 12.188
6.094
3.047
1.523
0.762
0.381
0.190
0.127
Peripheral Clock Frequency (MHz) - XC886
C
u
rre
n
t (
m
A
)
X
Y