TLE5012B
SSC Registers
User’s Manual
68
Rev. 1.2, 2018-02
6.1.2
Communication Examples
This chapter gives some short SSC communication examples. The sensor has to be selected first via CSQ, and
SCK must be available for the communication.
Figure 6-4 SSC command to read angle value
Figure 6-5 SSC command to read angle speed and angle revolution
Figure 6-6 SSC command to change Interface Mode2 register
Micro
‐
controller
TLE5012B
1.
Command:
1_0000_0_000010_0001
R/W_Lock_UPD_ADD_ND
2.
Read
Data:
1_xxxxxxxxxxxxxxx
Transmit
angle
value
3.
Safety
Word:
1_1_1_1_xxxx_xxxxxxxx
Transmit
safety
word
Micro
‐
controller
TLE5012B
1.
Command:
1_0000_0_000011_0010
R/W_Lock_UPD_ADD_ND
2.
Read
Data:
1_xxxxxxxxxxxxxxx
Transmit
angle
speed
3.
Read
Data:
1_xxxxxx_xxxxxxxxx
Transmit
angle
revolution
4.
Safety
Word:
1_1_1_1_xxxx_xxxxxxxx
Transmit
safety
word
Micro
‐
controller
TLE5012B
1.
Command:
0_1010_0_001000_0001
R/W_Lock_UPD_ADD_ND
2.
Write
Data:
0_00010000000_1_0_01
Set
ANG_Range
080
H
,
ANG_DIR:
1
B
,
PREDICT:
0
B
,
AUTOCAL:
01
B
3.
Safety
Word:
1_1_1_1_xxxx_xxxxxxxx
Transmit
safety
word