TLE5012B
Interfaces
User’s Manual
31
Rev. 1.2, 2018-02
5.2
Synchronous Serial Communication (SSC) Interface
5.2.1
SSC Timing Definition
Figure 5-1 SSC timing
SSC Inactive Time (CS
off
)
The SSC inactive time defines the delay time after a transfer before the TLE5012B can be selected again.
Table 5-2
SSC push-pull timing specification
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
SSC baud rate
f
SSC
8.0
Mbit/s
1)
1) Not subject to production test - verified by design/characterization
CSQ setup time
t
CSs
105
ns
CSQ hold time
t
CSh
105
ns
CSQ off
t
CSoff
600
ns
SSC inactive time
SCK period
t
SCKp
120
125
ns
SCK high
t
SCKh
40
ns
SCK low
t
SCKl
30
ns
DATA setup time
t
DATAs
25
ns
DATA hold time
t
DATAh
40
ns
Write read delay
t
wr_delay
130
ns
Update time
t
CSupdate
1
μ
s
See
SCK off
t
SCKoff
170
ns
SCK
t
CSs
t
SCKp
t
SCKh
t
CSh
CSQ
t
SCKl
t
CSoff
t
DATAs
DATA
t
DATAh