TLE5012B
Interfaces
User’s Manual
45
Rev. 1.2, 2018-02
Figure 5-10 Flow-Chart of Angle Calculation from the X-raw and Y-raw values
5.2.5.2
Angle Calculation with end-of-line calibration values
The TLE5012B already has pre-calibrated compensation parameters which can be used to calculate the angle
value (see
). Own compensation parameters can also be calculated end-of-line if desired. In that
case check the
Application Note TLE5009 Calibration
.
Angle
Calculation
Non-Orthogonality
Correction
Amplitude
Normalization
Temperature-dependent
Offset Calculation
Offset
Compensation
read
T_RAW
10bits
read
T25O
7bits
T_RAW
10
bits
‐
T25O
7bits
‐
439
read
TCO_X_T
7bits
read
TCO_Y_T
7bits
read
X_OFFSET
12bits
‐
Ox
12bits
+
x
read
Y_OFFSET
12bits
Oy
12bits
+
x
read
SYNCH
12bits
x
Y1
16bits
read
ADC_X
16bits
read
ADC_Y
16bits
+
X1
16bits
+
Y2
16bits
X2
16bits
read
ORTHO
12bits
sin(
‐
ORTHO)
cos(
‐
ORTHO)
‐
/
x
Y3
16bits
X3
16bits
read
ANG_BASE
12bits
α
atan(Y3/X3)
‐
SYNCH
14bits
>>7
>>7
+2^14
>>14