TLE5012B
SSC Registers
User’s Manual
89
Rev. 1.2, 2018-02
PREDICT
2
w
Prediction
Prediction of angle value based on current angle speed
(see data sheet).
Note: In case of changing a PREDICT, AUTOCAL should
be deactivated as explained under
.
0
B
prediction disabled
1
B
prediction enabled
Reset: derivate-specific
AUTOCAL
1:0
w
Autocalibration Mode
Automatic calibration of offset and amplitude
synchronicity for applications with full-turn. Only 1 LSB
corrected at each update. CRC check of calibration
registers is automatically disabled if AUTOCAL activated.
Autocalibration is described in the data sheet. Also see
.
00
B
no auto-calibration
01
B
auto-cal. mode 1: update every angle update cycle
(FIR_MD setting)
10
B
auto-cal. mode 2: update every 1.5 revolutions
11
B
auto-cal. mode 3: update every 11.25°
Reset: derivate-specific
1) Autocalibration and Revolution Counter work only for ANG_RANGE = 080
H
. Activated autocalibration forces 360° angle
range regardless of ANG_RANGE setting.
Field
Bits
Type
Description