![Indel 610535700 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/indel/610535700/610535700_hardware-manual_2051354049.webp)
Indel motion boards
Fieldbus systems
8.3
Error messages
Stop, deactivated
0x0000'0001
Ucc below Ucc min
0x0000'0002
Ucc above Ucc max
0x0000'0004
I2t exceeded > 120%
0x0000'0008
Output stage overheated
0x0000'0010
Motor temp exceeded
0x0000'0020
Motor short-circuit / IGBT protection
0x0000'0040
Resolver SinCos error
0x0000'0080
Maximum rotational speed exceeded
0x0000'0100
Safety relay not switched on
0x0000'0200
Auto-commutation error
0x0000'0400
Power end stop reached
0x0000'0800
Phase error
0x0000'1000
PWM watchdog: Interrupt overrun
0x0000'2000
missing Exteral Enable
0x0000'4000
missing (Motor) configuration
0x0000'8000
Feldbus Watchdog
0x0001'0000
8.4
Warnings
Ucc below Ucc ok
0x0000'0001
Ucc is set up and OK
0x0000'0002
Warning Iq_max reached
0x0000'0004
Warning output phase hot
0x0000'0010
Warning I2t exceeded
0x0000'0020
Motor temp exceeded
0x0000'0040
100% modulation exceeded
0x0000'0080
Warning unloading time exceeded
0x0000'0100
Rev 1.31; 04/11/2013