![Indel 610535700 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/indel/610535700/610535700_hardware-manual_2051354046.webp)
Operation
Indel motion boards
7
Operation
7.1
Braking resistor
It is highly recommended that a braking resistor be used on all motion boards.
e.g. 150 Ohm 2W for minimum braking energy destruction.
The braking resistance must be dimensioned in accordance with the application.
7.2
Motion boards with an ethernet interface
The following conditions must be met in order to be able to speak to the MAX-2,4,10 motion boards or
the AX4 board via the ethernet interface:
●
Ethernet communication must run at 1GHz. In addition, a 1GBit-enabled switch can also be
used in order to use PCs or laptops with a 100MBit interface
●
The address switch on the motion board must be set to 0x4
●
The GinLink pin Gin-Out is used for the ethernet connection
Page 46/54