![Indel 610535700 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/indel/610535700/610535700_hardware-manual_2051354016.webp)
Technical details
Indel motion boards
Analogue inputs and outputs
Analogue inputs and outputs
MAX2,4
MAX-10
AX4
Number of analogue inputs
14
4
-
Ranges
V
± 10
± 1
± 0.1
± 5
Converter time / channel
Khz
4
8 … 12
Resolution
Bit
16
16
Average filter
1 … 256
1 … 256
Number of analogue outputs
4
-
-
Range
V
± 10
Power per channel I
MAX
mA
5
Resolution
Bit
16
Accuracy
1
‰
Once switched on, the output of the analogue outputs is -12V over 300ms.
Accuracy of analogue inputs
Accuracy of ana-
logue inputs
Measuring range
Relative
accuracy of
individual measure-
ment
Relative accuracy
averaged for 100
values
Absolute
accuracy
± 10 V
Bit
14
15
14
± 1 V
Bit
13
14
13
± 0.1 V
Bit
12
14
12
Optimum stability of measurement values is achieved once
the unit has been switched on for 15min.
The accuracy specifications apply at the operating temperature.
Interfaces
Interfaces
INFO-MAX2,4
GIN-MAX2,4
GIN-MAX10
GIN-AX4
Serial interface
RS232
1
1
1
1
Baud rate
RS232
115'200
115'200
115'200
115'200
Protocols: Modbus
INFO-link interface
11MBit
Ethernet interfaces
2 x GinLink or 1 x Ether-
net, 1x GinLink
1GBit
-
2
2
2
IMP interface
Number of participants
-
-
-
1
5V supply (IMP bus)
mA
-
-
-
800
Page 16/54
04/11/2013; Rev 1.31
Содержание 610535700
Страница 1: ...Hardware Manual Indel motion boards Made in Switzerland Rev 1 31 Indel AG 04 11 2013 Language English...
Страница 51: ...Indel motion boards Sales and service 9 5 Declaration of conformity Rev 1 31 04 11 2013 Page 51 54...