112
IE
BG
SK
1-19
C43
• Extension pipes and elbows push-fittings. To
install snap-fit extensions with other elements of
the flue extraction elements assembly, proceed as
follows: install the pipe or elbow with the male
side (smooth) in the female section (with lip
seal) up to the stop on the previously installed
element. This will ensure sealing efficiency of the
coupling.
• Installation clearance (Fig. 1-19). The minimum
installation clearance measurements of the Ø
80/80 separator terminal kit have been stated in
some limit conditions.
• Extensions for Ø 80/80 separator kit. The
maximum vertical straight length (without
bends) that can be used or Ø 80 intake and
exhaust pipes is 41 metres, independently to
whether they are used for intake or exhaust.
The maximum horizontal straight length (with
bend in suction and in exhaust) that can be used
or Ø 80 intake and exhaust pipes is 36 metres
independently to whether they are used for
intake or exhaust.
N.B.:
to favour the removal of possible condensate
forming in the exhaust pipe, tilt the pipes towards
the boilers with a min. slope of 1.5%. (Fig. 1-20).
When installing the Ø 80 ducts , a section clamp
with pin must be installed every 3 metres.
• Pripojenie predlžovacieho potrubia a kolien
pomocou spojok. Pri inštalácii prípadného
predlženia pomocou spojok k ďalším prvkom
dymového systému je treba postupovať takto:
Výfukovú rúru alebo koleno zasuňte až na do-
raz vnútornou stranou (hladkou) do vonkajšej
strany (s okrajovým tesnením) inštalovaného
prvku. Týmto spôsobom dosiahnete dokonale
tesného spojenia jednotlivých častí súpravy.
• Inštalačné obvodové rozmery (Obr. 1-19).
Sú uvedené minimálne obvodové rozmery
inštalácie koncovej rozdeľovacej súpravy o pri-
emere 80/80 v medzných podmienkach.
• Predlžovacie kusy pre deliacu súpravu o priemere
80/80. Maximálna lineárna dĺžka (bez kolien)
vertikálne použiteľná pre nasávacie a výfukové
rúry o priemere 80 je 41 metrov, nezávisle
na tom, či sú použité pre nasávanie alebo pre
výfuk. Maximálna lineárna dĺžka (s kolenom
u nasávania a výfuku) horizontálne použiteľná
pre nasávacie a výfukové rúry o priemere 80 je
36 metrov, nezávisle na tom, či sú použité pre
nasávanie alebo pre výfuk.
Poznámka:
Aby ste napomohli eliminácii
prípadného kondenzátu, ktorý sa tvorí vo výfuko-
vom potrubí, je nutné nakloniť potrubie v smere
kotla s minimálnym sklonom 1,5% (Obr. 1-20). Pri
inštalácii potrubia o priemere 80 je nutné každé tri
metre inštalovať ťahový pás s hmoždinkou.
• Съединение чрез снаждане на тръби удължители и
колена. За инсталиране на евентуални удължители
чрез снаждане с другите димоотводни елементи,
трябва да се работи както следва: съединява се
тръбата или концентричното коляно с мъжката
страна (гладка), към женската страна (с гартитури
с устни) на предходно инсталирания елемент
до упор, като по този начин се постига добро
съединение и уплътнение на елементите.
• Пространство за инсталация (Сх. 1-19).
Представени са минималните инсталационни
разстояния за кита терминал сепаратор Ø 80/80
при ограничени условия.
• Удължители за кит сепаратор Ø 80/80.
Максималната дължина по права линия (без
завои) вертикално, използваема за засмукващи
и отвеждащи тръби Ø80 е 41 метра, независимо
дали същите се използват за засмукване или за
отвеждане. Максималната праволинейна дължина
(със кривка при засмукване и при отвеждане) в
хоризонтал използваема за тръби за засмукване
и отвеждане Ø 80 е 36 метра независимо дали се
използват за засмукване или за отвеждане.
N.B.:
за улесняване премахването на
евентуаленконденз, образуващ се в тръбата за
отвеждане трябва, да се наведят тръбите по посока
на топлогенератора с минимален наклон от 1,5% (Сх.
1-20). По време на инсталирането на тръбопроводите
Ø 80 трябва да се инсталира на всеки 3 metri una
fascetta rompitratta con tassello.
1-20
C83
Minimum slope 1,5%
Minimálny sklon 1,5%
Минимален наклон 1,5%