16
GB
Contents
1
Operating Elements and Connections 16
1.1
Front panel . . . . . . . . . . . . . . . . . . . . . 16
1.2
Rear panel . . . . . . . . . . . . . . . . . . . . . . 16
1.3
Control panel DRM-880WP . . . . . . . . . 17
2
Safety Notes . . . . . . . . . . . . . . . . . . . 17
3
Applications . . . . . . . . . . . . . . . . . . . . 17
4
Setting up and Connecting the Unit 17
4.1
Signal sources . . . . . . . . . . . . . . . . . . . 17
4.2
Amplifiers or other units . . . . . . . . . . . 17
4.3
External switching signals . . . . . . . . . . 17
4.4
Units to be controlled . . . . . . . . . . . . . 17
4.5
Control panel DRM-880WP . . . . . . . . . 17
4.6
Computer . . . . . . . . . . . . . . . . . . . . . . 17
4.7
Mains connection . . . . . . . . . . . . . . . . 18
5
Operation . . . . . . . . . . . . . . . . . . . . . . 18
5.1
Switching on/off . . . . . . . . . . . . . . . . . . 18
5.2
Selecting a configuration . . . . . . . . . . . 18
5.3
System settings . . . . . . . . . . . . . . . . . . 18
5.3.1 Setting the IP address . . . . . . . . . . . . . 18
5.3.2 Selecting an interface . . . . . . . . . . . . . 18
5.3.3 Unit number for RS-485 . . . . . . . . . . . 18
5.3.4 Retrieving switching combinations . . . 18
5.3.5 Linking switching combinations
to configurations . . . . . . . . . . . . . . . . . 19
5.4
Status LEDs . . . . . . . . . . . . . . . . . . . . 19
5.5
Operation via DRM-880WP . . . . . . . . . 19
5.5.1 Setting up the control panel . . . . . . . . 19
6
Remote Control via a Computer . . . 19
6.1
Installing PC software . . . . . . . . . . . . . 19
6.1.1 Installing an interface driver . . . . . . . . 19
6.2
Starting the PC software . . . . . . . . . . . 19
6.2.1 Adding units . . . . . . . . . . . . . . . . . . . . 19
6.2.2 Connecting or disconnecting units . . . 20
6.2.3 Naming a unit . . . . . . . . . . . . . . . . . . . 20
6.2.4 Calling up the configuration window . . 20
6.2.5 Removing units . . . . . . . . . . . . . . . . . . 20
6.2.6 Saving a unit constellation . . . . . . . . . 20
6.2.7 Loading a unit constellation . . . . . . . . . 20
6.2.8 Changing the interface . . . . . . . . . . . . 20
6.2.9 Setting the ID number or the IP address 20
6.2.10 Exiting the program . . . . . . . . . . . . . . 21
6.3
Views . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.3.1 Unit for signal delay . . . . . . . . . . . . . . . 21
6.4
Configuring inputs . . . . . . . . . . . . . . . . 21
6.4.1 Selecting the signal level . . . . . . . . . . . 21
6.4.2 Selecting the signal transmission type 21
6.4.3 Phantom power supply . . . . . . . . . . . . 21
6.4.4 Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.4.4.1 Main control “Master Input Gain” . . . . 21
6.4.5 Equalization (EQ) . . . . . . . . . . . . . . . . 21
6.4.5.1 Frequency response . . . . . . . . . . . . . 22
6.4.6 Feedback suppression (FBK) . . . . . . . 22
6.4.7 Phase reversal . . . . . . . . . . . . . . . . . . 22
6.5
Configuring outputs . . . . . . . . . . . . . . . 22
6.5.1 Assigning/ Mixing input signals . . . . . . 22
6.5.2 Signal delay . . . . . . . . . . . . . . . . . . . . . 22
6.5.3 High pass filter and low pass filter . . . . 22
6.5.4 Equalization . . . . . . . . . . . . . . . . . . . . . 22
6.5.4.1 Frequency response . . . . . . . . . . . . . 23
6.5.5 Compressor . . . . . . . . . . . . . . . . . . . . . 23
6.5.6 Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.5.7 Limiter . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.5.8 Phase reversal . . . . . . . . . . . . . . . . . . 24
6.5.9 Main control . . . . . . . . . . . . . . . . . . . . . 24
6.6
Status display . . . . . . . . . . . . . . . . . . . 24
6.7
Muting . . . . . . . . . . . . . . . . . . . . . . . . 24
6.8
Linking channels . . . . . . . . . . . . . . . . . 24
6.9
Copying adjustments . . . . . . . . . . . . . . 24
6.9.1 Copying adjustments of an input . . . . . 24
6.9.2 Copying adjustments of an output . . . .24
6.10 Renaming inputs and outputs . . . . . . . 24
6.11 Managing configurations . . . . . . . . . . . 24
6.11.1 Saving configurations on the computer 24
6.11.2 Loading configurations
from the computer . . . . . . . . . . . . . . . 25
6.11.3 Saving configurations on the unit . . . 25
6.11.4 Loading configurations from the unit . 25
6.11.5 Extra configurations . . . . . . . . . . . . . 25
6.12 Switching outputs . . . . . . . . . . . . . . . . 25
6.12.1 Renaming switching outputs . . . . . . . 25
6.12.2 Saving a switching combination
on the unit . . . . . . . . . . . . . . . . . . . . .25
6.12.3 Saving a switching combination
on the computer . . . . . . . . . . . . . . . . 25
6.12.4 Loading a switching combination
from the computer . . . . . . . . . . . . . . . 26
6.13 Switching inputs . . . . . . . . . . . . . . . . . 26
6.13.1 Enabling or disabling inputs . . . . . . . 26
6.13.2 Selecting the logic type (high/ low) . . 26
6.13.3 Selecting priorities . . . . . . . . . . . . . . . 26
6.14 Selecting the interface mode . . . . . . . . 26
6.15 Exiting a configuration window . . . . . . 26
7
Specifications . . . . . . . . . . . . . . . . . . 27
All operating elements and connections de -
scribed can be found on the fold-out page 3.
1 Operating Elements and
Connections
1.1 Front panel
1 LED PHANTOM POWER; lights up when the
phantom power supply for the microphone
inputs is switched on
2 LC display
3 Buttons PRESET 1 – 6 for retrieving the con-
figurations previously saved
To call up the system setting menu, keep but-
ton 5 pressed for several seconds. The func-
tions of the system setting buttons are
described in chapter 5.3.
4 Status LEDs for the input/output channels
CH 1 – CH 8
LIMITER – limiter or compressor active
CLIP – input overloaded (after EQ)
SIGNAL – signal for output signal available
FBK – feedback suppression active
MIC – input for microphone
LINE – input for line signal source
5 USB jack, type B, to connect a computer for
remote control and for configuration of the
DRM-880LAN
1.2 Rear panel
6 POWER switch
7 Mains jack for connection to a socket (230 V~/
50 Hz) via the mains cable supplied
8 Support for the mains fuse;
always replace a blown fuse by a fuse of the
same type
9 RJ45 jack TCP/IP to connect a computer for
remote-controlled operation of the DRM-
880LAN via Ethernet; the two LEDs above
the jack indicate that the connection is being
established or that data is being transferred
10 RJ45 jack RS485 IN to connect a computer
for remote-controlled operation or to connect
the remote-control panel DRM-880WP (fig. 3)
11 RJ45 jack RS485 OUT to connect an addi-
tional unit to be remote-controlled by the
computer that is connected to jack RS485 IN
(10)
12 Switching outputs S1 – S4 as screw termi-
nals*
13 Switching inputs S1 – S4 as screw terminals*
to retrieve the extra configurations previously
saved
14 Balanced audio signal outputs CH 1 – CH 8
as screw terminals*
15 Balanced audio signal inputs CH 1 – CH 8 as
screw terminals*
* For easier connection, the entire terminal block may
be removed from the unit.