279
9.5.5
Redundancy Function
Extender modules with redundant connectors for interconnect cables can be simultaneously operated with
both connectors at a single Matrix or a Matrix Grid (from firmware version V04.00).
The connector labeled with
Link 1
at the extender module is meant for the primary connection. If the
connection on CON Unit or CPU Unit side is interrupted due to any problem, the connection will be
automatically re-established through the second connector labeled with
Link 2
.
For this kind of redundancy function, there is no need for any configuration of the matrix or the extender
modules.
If needed, you can manually switch between
Link 1
and
Link 2
at the CON Unit (see chapter 9.2.4,
page 266).
Fig. 212
OSD Menu Switch
Select
Switch
in the main menu.
When using redundant extender modules, the respectively active connector is shown in this view under
EXT list
in the field
CON/CPU Data
. If the first connector (
Link 1
) is active, it will be highlighted with
:1
behind the respective extender. If the second connector (
Link 2
) is active, this will be highlighted with
:2
.