Draco tera flex
Configuration via OSD
77
The following parameters can be configured:
Network Interface #1
Field
Entry
Description
Dual Interface
Y
Redundant network connection is deactivated
N
Redundant network connection is activated (default)
DHCP
Y
The network settings are automatically supplied by a DHCP
server.
Note:
If DHCP is activated and there is no physical network
connection available, the boot times might increase.
N
Function not active (default)
IP Address
Byte
Input of the IP address if DHCP is not active (default:
192.168.100.99)
Subnet Mask
Byte
Input of the subnet mask in the form "255.255.255.0" if DHCP is
not active (default: 255.255.255.0)
Gateway
Byte
Input of the subnet mask in the form "192.168.1.1" if DHCP is
not active
MAC Address
Byte
Cannot be changed, is retrieved automatically
Multicast
Byte
Input of the Multicast address if there is a Matrix Grid in use
within a Multicast group (default: 255.255.255.255)
Network Services
Field
Entry
Description
API Service #1
Y
LAN interface at the matrix activated for access via
management software (default, API service port 5555/5565)
N
Function not active
Grid Service #1
Y
Activate Grid interface at the matrix for access via management
software (Grid Service Port 5557/5567)
N
Function not active (default)
SSL Services #1
Y
Activate SSL encryption for API, management software (API),
and Matrix Grid communication.
N
Function not active (default)
Syslog #1/#2
Y
Syslog server for status request is active
N
Function not active (default)
Syslog Server #1/#2
Byte
Input of the IP address of the Syslog servers in the form
“192.168.1.1” and of the Syslog port (default: 514)
The LDAP settings are explained in the chapter 7.3.6, page 79.
Log Levels
Field
Entry
Description
Trace
DEB
Activate debug messages in Trace (default: N)
Note:
The debug messages are exclusively for matrix
diagnostics. They only should be activated after consultation
with the manufacturer. Otherwise, an increased traffic of data
might limit the performance of the controller board.