Installation
Draco tera flex
58
6
Installation
NOTICE
Please verify that interconnect cables, interfaces, and handling of the devices comply with the
requirements (see chapter 10, page 314).
First-time users are recommended to set up the system in a test environment that is limited to a single
room. This makes it easier to identify and solve any cabling problems, and experiment with your system
more conveniently.
6.1
Preparing the Matrix for Rack Mounting
NOTICE
Due to the construction of a matrix with 16, 32 and 40 ports into a 19’’ rack, it is recommended to use an
additional subfloor below the matrix. It should be used in addition to the provided mounting brackets.
The supplied mounting brackets are required for mounting the KVM matrix switch.
1. For front rack mounting, remove the front and middle screws on both sides of the cover.
2. For rear rack mount, remove the rear and middle screws on both sides of the cover.
3. Mount the mounting bracket in the desired position using the screws on the cover/chassis.
6.2
Setting up the Matrix
6.2.1
Prerequisites for failure-free Installation of a Matrix Setup
To achieve the best possible performance and results with the matrix system, we recommend using the
supplied cables. If you need a replacement, please use the spare parts specified for this device, which can
be requested from the manufacturer if required.
To achieve a failure-free installation of a matrix system, we recommend to first establish a point-to-point
connection between a CPU Unit and a CON Unit before connecting to the matrix as follows:
Source (computer, CPU) - CPU Unit - Link - CON Unit - console (monitor, keyboard, mouse)
Ensure that this most simplistic setup works.
Then continue as follows.
1. First connect the CPU Unit to the source (computer, CPU) by using the provided connection cables.
2. Connect the CPU Unit to the CON Unit by using the interconnect cables (Cat X or fiber).
3. Connect the monitor, keyboard, and mouse to the CON Unit.
4. Connect the power supply units to the CPU Unit and CON Unit.
5. Power up the CPU Unit and CON Unit.
6. Boot the source (computer, CPU) and check that everything works correctly.