Configuration via OSD
Draco tera flex
106
7.8
Configuring Console Settings
Connecting a CON Unit to the matrix creates an EXT Unit in the matrix, reading the serial number of the
CON Unit. An EXT Unit has to be assigned to a CON Device. Switching operation is only possible between
CON Device and CPU Device. All steps to create switchable CON Devices are described in this chapter.
Several Real CON Devices can be assigned to a Virtual CON Device to reduce operation efforts (see
chapter 7.8.6, page 115).
7.8.1
OSD Configuration for Mouse and Keyboard
The OSD configuration for mouse and keyboard is made in this menu. The settings for mouse and
keyboard are console-specific and can be set separately for each console.
Fig. 81
OSD Menu Configuration - EXT Units
The following parameters can be configured:
Field
Entry
Description
Hor. Speed 1/x
1 to 9
Adjustment of the horizontal mouse speed, 1 = slow, 9 = fast
(default: 4)
Ver. Speed 1/x
1 to 9
Adjustment of the vertical mouse speed, 1 = slow, 9 = fast
(default: 5)
Double-click
100 to 800
Adjustment of the time slot for a double-click (default: 200 ms)
Keyboard layout
Region
Set the OSD keyboard layout according to the used keyboard
(default: German (DE))
Video Mode
Variable or
specific
resolution
Resolution that is used when opening OSD