7.3.2
Enabling Automatic Creation of CPU and CON Devices
Settings for automatic creation of CPU and CON Devices when a new CON extender module or CPU
extender module is connected are set in this menu.
Fig. 64
OSD Menu Configuration - System - Automatic ID
The following parameters can be configured:
Field
Entry
Description
Enable Auto Config
Y
Automatic creation of a new CPU or CON Device if new
extender modules are connected (default)
N
Function not active
ID Real CPU Device
Numerical
Initial value of the automatic ID for real CPUs (default: 1000)
ID Virtual CPU Device
Numerical
Initial value of the automatic ID for virtual CPUs (default: 2000)
ID Real CON Device
Numerical
Initial value of the automatic ID for real CONs (default: 3000)
ID Virtual CON Device
Numerical
Initial value of the automatic ID for virtual CONs (default: 4000)
To set up the automatic creation of CPU Devices or CON Devices, proceed as follows:
1. Select
Configuration > System
in the main menu.
2. Modify the desired settings.
3. Click the
Okay
button to confirm your entries.