Draco tera flex
Configuration via Management Software
155
8.4.8
Setting SNMP Function
The SNMP function allows all function-critical and safety-critical elements of the matrix to be monitored and
queried. This function complies with the RFC 1157 conformal standard. Two SNMP servers can be used at
the same time. Enabling the SNMP function, the unencrypted SNMP monitoring (SNMPv2) is activated. An
SNMPv3 User for encrypted SNMP monitoring (SNMPv3) can be set in the user settings (see
chapter 8.5.1, page 165) and the login data for an SNMPv3 User at the SNMP server can be set in the
default settings (see section on page 159).
NOTICE
When using SNMP monitoring, for reasons of access security, the use of a dedicated network according
to the IT-Grundschutz catalog is recommended. The read only community for the MIB file is
draco
.
NOTICE
For an activation of the SNMP agent function or the SNMP server function, a restart of the matrix or the
CPU board is necessary. Restarting the matrix or the CPU board can take several minutes, and the
matrix is not available during the restart.
The settings for the SNMP monitoring are set in this menu:
Fig. 114
Management software menu System Settings - Network - SNMP