Configuration via Management Software
Draco tera flex
156
The following parameters can be configured:
SNMP Agent
Traps
Description
SNMP Agent
Permission for an active query of the SNMP agent for traps is granted.
This activation is a prerequisite for using the SNMP server.
Port
The SNMP port is called up automatically (default: 161).
Configured SNMPv3
User
Name of the SNMP user (default: snmp)
Read-Only
Community String
The read-only community string for the MIB file is
draco
.
SNMP Trap
The SNMP agent must be activated to activate the SNMP traps.
Traps
Description
Enable Traps
Activates the active sending of trap messages from the SNMP agent to the
SNMP server
SNMP Server
Input of the IP address of the SNMP server in the form “192.168.1.1”
Port
Input of the SNMP port (default: 162)
Select All
Select all traps
Status
Notification about matrix status
Temperature
Notification about temperature within the matrix
Insert I/O Board
Not available*
Remove I/O Board
Not available*
Invalid I/O Board
Notification about a wrong firmware installed on the I/O board
Insert Extender
•
Notification about a newly connected extender to the matrix, notification
about a switched-on extender
•
Notification about a newly established link between extender and matrix
Remove Extender
•
Notification about a removed extender from the matrix
•
Notification about a switched off extender
•
Notification about an interrupted link between extender and matrix
Switch Command
Notification about a performed switching operation at the matrix
Fan Tray #1
Notification about the fan status on the left side of the matrix (interface view)
Fan Tray #2
Notification about the fan status on the right side of the matrix (interface view)
Power Supply #1
Notification about the status of power supply unit #1
Power Supply #2
Notification about the status of power supply unit #2
Power Supply #3
Not available*
Power Supply #4
Not available*
* Only for Draco tera enterprise matrices
Содержание Draco tera flex Cat X 1G K480-C16