Configuration via Management Software
Draco tera flex
254
Updating the Extender Firmware by passing the Extender Firmware from the Memory of the I/O Board
When updating an identical or an older firmware version than the version currently installed, the
Enable
Downgrade
option in the upper part of the working area must be enabled.
To update the extender firmware via standard update, proceed as follows:
1. Click the
Update
button to start the update.
Just before the update process, all I/O boards will be set into the
Service Mode
and retrieved gradually
after finishing the respective updates. During Service Mode, all matrix functions are disabled on the I/O
boards on which an update is currently performed. An OSD picture indicates the activation of the Service
Mode and is displayed on all monitors connected to those CON Units that are connected to the matrix.
2. The progress of the update is displayed in the working area.
3. Check the update messages in the message field after the update if the updates for all extender
modules have been installed correctly.
Fig. 194
Management software menu Status & Updates - Update Extender Firmware - Parallel Mode -
Update