Draco tera flex
Installation
59
6.2.2
Initial Commissioning of the Matrix
1. Connect the monitor, keyboard, and mouse to a functionally tested CON Unit.
2. Connect the CON Unit to an I/O port of the matrix by using the interconnect cables (Cat X or fiber).
3. Connect the matrix and the CON Unit to the power supply.
4. Power up the matrix and wait until the boot process is finished (status LED flashes green).
5. Open the OSD via keyboard command
2x <Left Shift>, <o>
.
The
Caps Lock
and
Scroll Lock
LEDs on the keyboard are flashing, and the OSD is opened on the
display showing the KVM List view.
6. Press the
<ESC>
key to enter the advanced menus.
The OSD can be operated via keyboard and mouse.
7. Select
Configuration
in the main menu.
8. Login with administrator rights (see chapter 7.1, page 65).
9. Configure initially as requested (see from chapter 7.2, from page 66).
Optional: Establish a network connection between the matrix and the management software to set an
extended configuration (from chapter 6.4, page 60).
The default IP address is 192.168.100.99 and DHCP is deactivated.
After the configuration of the system it is recommended to save the configuration by selecting
Configuration > Save
(see chapter 7.10.1, page 129) and restart the matrix by selecting
Restart Matrix
(see chapter 9.9.1, page 300).
When installing several matrices at the same time, it is strongly recommended to install them in sequence
and to assign unique IP addresses to avoid IP address conflicts.
6.3
Connecting the Matrix to the Sink (Console) and the Sources
(Computer, CPUs)
6.3.1
Connecting the Sink (Console) to the Matrix
1. Connect the monitor, keyboard, and mouse to the CON Unit.
2. Connect the CON Unit to an I/O port of the matrix by using the interconnect cables (Cat X or fiber).
3. Connect the matrix and the CON Unit to the power supply.
4. Connect the power supply units to the CON Unit.
5. Establish the power supply to the CON Unit.
6. Check the basic function of the CON Unit by opening the OSD via keyboard command
<Hot Key>,
<o>
.
6.3.2
Connecting the Sources (Computer, CPU) to the Matrix
1. Connect the source (computer, CPU) to the CPU Unit by using the provided connection cables.
2. Connect the CPU Unit to the matrix using the interconnect cables (Cat X or fiber).
3. Connect the power supply units to the CPU Unit.
4. Establish the power supply to the CPU Unit.
Содержание Draco tera flex Cat X 1G K480-C16