Draco tera flex
Configuration via OSD
75
Field
Entry
Description
Force Connect
Y
The user can connect to every single CPU Device as an
operator, including those that are related to another user.
Note:
The previous user is set to Video Only status.
To share K/M control,
Force Connect
has to be activated.
N
Function not active (default)
Force Disconnect
Y
Extension of
Force Connect
: If the user connects as an
operator to a CPU Device already related to another user, the
previous user will be disconnected.
Note:
To share K/M control
Force Disconnect
has to be
deactivated and
Enable Video Sharing
has to be activated.
N
Function not active (default)
CPU Auto Connect
Y
If a CON Device is not connected to a CPU Device, you can
establish an automatic connection to the next available CPU
Device by hitting any key or mouse button.
N
Function not active (default)
CPU Timeout [min]
0 to 999
minutes
Period of inactivity after which a CON Device will be
automatically disconnected from its current CPU Device
(default: 0 minutes)
Keyboard Connect
Y
Activate request of K/M control by keyboard event (key will be
lost)
N
Function not active (default)
Mouse Connect
Y
Activate request of K/M control by mouse event
N
Function not active (default)
Release Time [sec]
0 to 999
seconds
Period of inactivity of a connected console after which K/M
control can be requested by other consoles connected to the
CPU Device.
Note:
Set
0
for an immediate transfer in real-time.
Only one console can have keyboard and mouse control at a
time. The other consoles that are connected to the same CPU
Device have a Video Only status (default: 10 seconds)
Macro Single Step
Y
Execute macro commands sequentially
N
Function not active (default)
To configure shared operation, proceed as follows:
1. Select
Configuration > Switch
in the main menu.
2. Activate the
Enable Video Sharing
function.
3. Activate the
Force Connect
function.
4. Activate the
Keyboard Connect
function if taking over control by a keyboard event should be possible.
5. Activate the
Mouse Connect
function if taking over control by a mouse movement should be possible.
6. Define a
Release Time
of inactivity (0 to 999 seconds) after which KVM control can be taken over.
7. Click the
Okay
button to confirm your settings.
Keyboard Connect
and / or
Mouse Connect
are only effective if
Force Connect
and / or
CPU Auto
Connect
are activated.
If the
Keyboard Connect
and / or
Mouse Connect
options are enabled, the
Keyboard Connect
and/or
Mouse Connect
will not take effect until the time interval entered in the
Release Time
has elapsed.
Содержание Draco tera flex Cat X 1G K480-C16