Draco tera flex
Configuration via Management Software
187
Fig. 137
Management software dialog Activate USB Fixed Port
After restart of the I/O board, the parameters and settings of the USB 2.0 extender module are shown
in the working area of the respective EXT Unit.
9. The USB 2.0 CPU/CON EXT Unit has to now be either assigned to an existing CPU/CON Device or a
new CPU/CON Device has to be created for the assignment:
•
for a
CPU Device
•
for a
CON Device
10. If you use parallel operation within the matrix, set the
Release Time
in the
System Settings > Switch
menu to
10 s
or more (see chapter 8.4.5, page 146).
11. Restart all I/O boards on which USB 2.0 EXT Units have been configured or alternatively restart the
matrix.
The USB 2.0 EXT Units are now configured and can be used.
Manually created EXT Units are always set as fixed port EXT Units. This configuration is necessary if you
want to switch, e.g., USB 2.0 connections via the matrix.
To make a fixed port available again for Flex Port EXT Units after deleting a fixed port EXT Unit, a restart of
the I/O board is necessary.