12.6 Failure at the Matrix
Diagnosis
Possible reason
Measure
Port definitions as
USB 2.0 invalid.
Restart of the matrix not yet
completed.
Restart the matrix.
No OSD access
possible.
Wrong Hot Key
Reset Hot Key if necessary (see
12.7 Failure at the Interconnection Port
12.7.1 Error Indication at the 1G Cat X Port
Fig. 249
LEDs of I/O module 1G Cat X
Diagnosis
Possible reason
Measure
LED 1 or LED 2
flashing orange
Connections CON Unit,
matrix, and CPU Unit.
Check connecting cables and connectors
(cable break, CPU/CON Unit offline).
Connect a 3G extender to a 3G port.
Contact dealer if necessary.
12.7.2 Error Indication at the 3G Cat X Port
Fig. 250
LEDs of I/O module 3G Cat X
Diagnosis
Possible reason
Measure
LED 1 or LED 2
flashing orange
Connections CON Unit,
matrix, and CPU Unit.
Check connecting cables and connectors
(cable break, CPU/CON Unit offline).
Connect a 1G extender to a 1G port.
Contact dealer if necessary.