Configuration via OSD
Draco tera flex
72
7.3.3
Setting Access Configuration
The access configuration is set in this menu.
Fig. 65
OSD Menu Configuration - Access
The following parameters can be configured:
Field
Entry
Description
Force User Login
Y
The user has to login with a username and a password once to
enter OSD. Thereafter the user remains logged in until he
explicitly logs out or an auto logout is affected.
Note:
When the
Force User Login
function is activated and a
user is logged in, only the user favorites are available. The CON
favorites are not accessible.
N
Function not active (default)
Enable User ACL
Y
CPU Device access is restricted according to the permissions in
the ACL (Access Control List).
•
User login is required.
•
Switching by keyboard Hot Keys requires a prior login.
N
Function not active (default)
Enable CON ACL
Y
CPU Device access is restricted according to the permissions in
the respective CON Device ACL (Access Control List). No login
required
N
Function not active (default)
Содержание Draco tera flex Cat X 1G K480-C120
Страница 84: ...Configuration via OSD Draco tera flex 84 ...