Draco tera flex
Configuration via Management Software
233
8. Select
Extender & Devices > CON Devices
in the task area of the Sub Matrix.
8.1. Click the
New Device
button.
A switchable CON Device will be created.
8.2. Enter an appropriate name for the Cascading CON Device into the
Name
field.
Fig. 172
Management software menu Extender & Devices > CON Devices - Cascading CON Device
8.3. Select the previously configured Cascading CON Unit in the
Extender available
list.
8.4. Click the button to move the highlighted Cascading CON Unit to the
Extender assigned
list.
The assignment is displayed in the
Extender assigned
list.
8.5. Click the
Apply
button to confirm the assignment.
9. Click the
Deactivate Edit Mode
menu item in the toolbar.
The OSD of the Sub Matrix will immediately freeze and will be only accessible by using the keyboard
command
<Hot Key>, <s>, <o>
.
10. Restart all I/O boards on which any Master/Sub CON Units or CPU Units have been configured (see
chapter 9.10.3, page 307) or alternatively restart the matrix (see chapter 9.10.1, page 305).
11. Connect the Tie Lines to the matrices. Ensure that each
Cascade CON Device
on one matrix is
connected to
Cascade CPU Device
on the other matrix to achieve switching ability between two
matrices.
The Matrix Cascading is now configured and can be used.
Additional Tie Lines are configured accordingly. The use of cascading is described in chapter 9.2.7,
page 269.
Содержание Draco tera flex Cat X 1G K480-C120
Страница 84: ...Configuration via OSD Draco tera flex 84 ...