Configuration via Management Software
Draco tera flex
178
8.6
Main Extender Settings
8.6.1
Extender Settings
The matrix automatically recognizes every extender module, physically connected to the matrix with a direct
cable connection, reads out its serial number and creates EXT Units automatically. This is the Flex Port
function of the matrix. Dual-Head extender modules will be recognized as two independent EXT Units.
Add-on modules are not created as independent EXT Units. The data of add-on modules is included in one
EXT Unit together with the associated extender module.
All EXT Units are managed in this menu. This includes the creation of new EXT Units and the deletion of
existing EXT Units.
NOTICE
The connection of a fixed port EXT Unit (e.g., USB 2.0) to a Flex Port can cause unintended results.
EXT Units for USB 2.0 extender modules have to be created manually (see chapter 8.7, page 186).
Fig. 127
Management software menu Extender & Devices - EXT Units
The following parameters are recognized automatically:
Field
Entry
Description
ID
Text
Numerical value of the KVM extender module ID.
The ID is provided by the extender module (serial number) and
cannot be changed.
Name
Text
Name of the EXT Unit