Configuration via Management Software
Draco tera flex
166
The following parameters can be configured:
Field
Entry
Description
ID
Numerical
Ident number of the user
Name
Text
For standard users it is the login name (case sensitive, input of
minimum 1 character up to 16 characters). Can be used to log in
to the OSD.
For LDAP Users it is the name (case sensitive, input of
minimum 1 character up to 16 characters). Can be used to log in
to the OSD.
For users synchronized via LDAP, it is the
sAMAccountName
,
automatically retrieved from the LDAP server. Can be used to
log in to the OSD.
Full Name /
Login Name /
AD CN=
Text
For standard users it is the full name (optional input of up to
32 characters). Can be used to log in to the OSD.
For LDAP Users it is the login name (case sensitive, input of
minimum 1 character up to 32 characters).
Can be used to log in to the OSD.
For users synchronized via LDAP, it is the userPrincipalName,
automatically retrieved. Can be used to log in to the OSD.
Password
Text
For standard users (optional input of up to 16 characters). Can
be used to log in to the OSD.
For LDAP Users (case sensitive, input of minimum 1 character
up to 16 characters). Can be used to log in to the OSD.
Priority
Value
Priority of the user
Administrator
Activated
•
User has administrator rights
•
Permission for system configuration and all switching
operations
Deactivated
Function not active
Super User
Activated
Permission to switch any CON Device to any CPU Device in
Extended Switching
Deactivated
Function not active
Power User
Activated
•
User has user rights
•
Permission to switch CON Devices to CPU Devices in
Extended Switching
according to the
CON Device ACL
or
User ACL
, but not in Private Mode
Deactivated
Function not active
SNMPv3 User
Activated
Permission to use SNMPv3 (encrypted)
Deactivated
SNMPv3 is not enabled
LDAP Login
Activated
Bind User for accessing the Active Directory
Deactivated
Function not active (default)
Auto Connect
Activated
Re-establish the previous user connection after login
Deactivated
Function not active
AD Synchronized
Activated
Enable synchronization with the Active Directory
Note:
LDAP Login has to be activated to use the
synchronization
Deactivated
Function not active
Содержание Draco tera flex Cat X 1G K480-C120
Страница 84: ...Configuration via OSD Draco tera flex 84 ...