Draco tera flex
Configuration via OSD
97
To configure a USB 2.0 EXT Unit, proceed as follows:
1. Select
Configuration > EXT Units
in the main menu.
2. Click the
New
button.
An EXT Unit with an eight-digit ID will be created, starting with digit
9
.
3. Enter an appropriate name for the EXT Unit in the
Name
field.
4. Enter the port number of the matrix the USB 2.0 extender module is currently connected into the
Port
field.
5. To configure the created extender as a CON Unit:
5.1. Set the
USB-CON
(
standalone
) option to
Y
(
C#1
in the
Input Signals
column).
5.2. Click the
Okay
button to confirm the setting.
6. To configure the created extender as a CPU Unit:
6.1. Set the
USB-CPU
(
standalone
) option to
Y
(
C#1
in the
Output Signals
column).
6.2. Click the
Okay
button to confirm the setting.
7. Click the
Okay
button to confirm the settings.
8. Restart the I/O board to activate the USB fixed port for the new EXT Unit.
After restart of the I/O board, the parameters and settings of the USB 2.0 extender module are shown
in the respective EXT Unit.
9. The USB 2.0 CPU/CON EXT Unit has to now be either assigned to an existing CPU/CON Device or a
new CPU/CON Device has to be created for the assignment:
•
for a
CPU Device
•
for a
CON Device
10. If you use parallel operation within the matrix, set the
Release Time
in the
System Settings > Switch
menu to
10 s
or more (see chapter 8.4.5, page 146).
11. Restart all I/O boards on which USB 2.0 EXT Units have been configured or alternatively restart the
matrix.
The USB 2.0 EXT Units are now configured and can be used.
Manually created EXT Units are always set as fixed port EXT Units. This configuration is necessary if you
want to switch, e.g., USB 2.0 connections via the matrix.
To make a fixed port available again for Flex Port EXT Units after deleting a fixed port EXT Unit, a restart of
the I/O board is necessary.