Configuration via Management Software
Draco tera flex
204
8.9
Configuring Console Settings
Connecting a CON Unit to the matrix creates an EXT Unit in the matrix, reading the serial number of the
CON Unit. An EXT Unit has to be assigned to a CON Device. Switching operation is only possible between
CON Device and CPU Device. All steps to create switchable CON Devices are described in this chapter.
Several Real CON Devices can be assigned to a Virtual CON Device to reduce operation efforts (see
chapter 8.9.6, page 221).
8.9.1
Configuring Mouse and Keyboard used in the Extender OSD
The OSD configuration for mouse and keyboard is made in this menu.
Fig. 151
Management software menu Extender & Devices - EXT Units - General OSD Data
The following parameters can be configured:
Field
Entry
Description
Horizontal Mouse
Speed [1/x]
1 to 9
Adjust the horizontal mouse speed, 1 = slow, 9 = fast (default: 4)
Vertical Mouse Speed
[1/x]
1 to 9
Adjust the vertical mouse speed, 1 = slow, 9 = fast (default: 5)
Double Click Time
[sec]
100 to 800
Adjust the time slot for a double-click (default: 200 ms)
Keyboard Layout
Region
Set the OSD keyboard layout according to the used keyboard
(default: German (DE))
Video Mode
Variable or
specific
resolution
Set the resolution that is used when opening the OSD
Содержание Draco tera flex Cat X 1G K480-C120