Device manual AS-i M4 Gateway Profibus DPV1 (AC1375, AC1376)
2012-02-23
Contents
6
12.8.14
Acyclic command 31 (1Fhex) – execute the extended safety monitor protocol
in the Safety-at-Work monitor once ..................................................................... 352
12.8.15
Acyclic command 33 (21hex) – read 7.4 diagnostic string of an AS-i slave......... 357
12.8.16
Acyclic command 34 (22hex) – read 7.4 parameter string of an AS-i slave ........ 360
12.8.17
Acyclic command 35 (23hex) – write 7.4 parameter string of an AS-i slave ........ 363
12.8.18
Acyclic command 36 (24hex) – acyclic standard read call to an AS-i slave
with CTT2 profile.................................................................................................. 365
12.8.19
Acyclic command 37 (25hex) – acyclic standard write call to an AS-i slave
with CTT2 profile.................................................................................................. 369
12.8.20
Acyclic command 38 (26hex) – acyclic manufacturer-specific read call to
an AS-i slave with CTT2 profile ........................................................................... 372
12.8.21
Acyclic command 39 (27hex) – acyclic manufacturer-specific write call to
an AS-i slave with CTT2 profile ........................................................................... 376
12.8.22
Acyclic command 50 (32hex) – read current configuration of AS-i slaves
0(A)...15(A) .......................................................................................................... 379
12.8.23
Acyclic command 51 (33hex) – read current configuration of AS-i slaves
16(A)...31(A) ........................................................................................................ 381
12.8.24
Acyclic command 52 (34hex) – read current configuration AS-i slaves
1B...15B ............................................................................................................... 382
12.8.25
Acyclic command 53 (35hex) – read current configuration AS-i slaves
16B...31B ............................................................................................................. 383
12.8.26
Acyclic command 54 (36hex) – read current parameters of the AS-i slaves ....... 384
12.8.27
Acyclic command 55 (37hex) – read current AS-i slave lists ............................... 386
12.8.28
Acyclic command 56 (38hex) – read projected configuration of AS-i slaves
1(A)...15(A) .......................................................................................................... 388
12.8.29
Acyclic command 57 (39hex) – read projected configuration of the AS-i
slaves 16(A)...31(A) ............................................................................................. 390
12.8.30
Acyclic command 58 (3Ahex) – read projected configuration of AS-i slaves
1B...15B ............................................................................................................... 391
12.8.31
Acyclic command 59 (3Bhex) – read projected configuration of AS-i slaves
16B...31B .............................................................................................................. 392
12.8.32
Acyclic command 96 (60hex) – save data non-volatilely in the flash memory
of the device ........................................................................................................ 393
12.8.33
Acyclic command 97 (61hex) – carry out settings in the device .......................... 394
12.8.34
Acyclic command 102 (66hex) – user menu ........................................................ 396
12.8.35
Acyclic command 105 (69hex) – read device features......................................... 400
13
Further functions for Profibus DPV1
13.1
AS-i diagnosis via Profibus DP .................................................................................. 402
13.1.1
Digital inputs ......................................................................................................... 402
13.1.2
Digital outputs ....................................................................................................... 403
13.1.3
Extended device-specific diagnosis for Profibus DP ............................................ 404
13.1.4
Diagnostic master flags (byte 10 / byte 36) .......................................................... 405
13.2
Set the Profibus slave address on the gateway ........................................................ 406
13.3
Read fieldbus parameters.......................................................................................... 408
14
Operation
14.1
Display of the list of detected slaves (LDS) ............................................................... 413
14.2
Display of the list of projected slaves (LPS) .............................................................. 416
14.3
Display list of activated slaves (LAS)......................................................................... 419
14.4
Display of the list of slaves with peripheral fault (LPF) .............................................. 422
14.5
Display of slave with peripheral fault ......................................................................... 425
14.6
Detect an unknown slave address............................................................................. 426
14.7
Number of AS-i voltage failures on the AS-i master .................................................. 427