Supplementary device manual DeviceNet interface in the AS-i ControllerE (AC1318, AC1324), Target from 15
2012-02-29
Function
The fieldbus modules
66
5.3.15
Module 13 – fieldbus data PLC output
10653
Data content
10648
Up to 128 bytes of freely definable data
Direction of data
10590
C
F
Data from the controller to the fieldbus interface
Module settings
10649
Value range = 0...128 [bytes]
0
module is deactivated
1...128
module is activated (details
data interpretation)
Data interpretation
10655
Module 13 contains output data from the controller PLC's point of view, i.e. data transmitted by the
controller e.g. to a higher-level PLC or a PC.
These data can be accessed via the PLC application program of the controller.
Access in the application program is carried out via the variables
-
PLC_Output[0]
to
-
PLC_Output[127]
.
In case of double word representation in the host PLC the following allocation of the individual bytes
results: