The input ENABLE controls the execution of the function. But
since with each call of the function the data array is transferred,
the function is a load for the plc cycle even in case of
ENABLE=FALSE. This is why SDO_READ should be skipped if
the function is not utilized.
The value for LENGTH should conform to the length of the
expected data object.